F. REMOVING DOOR (Figure 14)
(1)Remove the vent grille by two screws securing it to the outcase loosening.
(2)Lift up and draw the door.
NOTES:
•After replacing the door, be sure to check that the primary interlock switch, the secondary interlock switch and the interlock monitor switch is in good operating normally.
•After replacing the door, check for microwave energy leakage with a survey meter. Microwave energy leakage must be below the limit of 5mW/cm2 (With a 275 ml water load)
Figure 14
G. DISASSEMBLING DOOR (Figure 15)
(1)Remove the dielectric choke by using knife blade or small screw driver, etc.
(2)Remove two screws securing it to the door handle.
CAUTION: Be careful not to damage door seal plate with the screwdriver.
Door Screen
Figure 15