Liebherr LGex 910 manual Opening for external temperature sensor, Model LGUex Model LGex

Page 10

Opening for external temperature sensor

Opening for external temperature sensor

Model LGUex 1500

Model LGex 3410

 

Remove upper drawer before beginning work.

1. Drill marked section on the back of the appliance.

2. Pull out strain relief device (bot- tom left of interior container).

3.Feed sensor through opening and secure sensor cable with strain relief device.

Important!

Position the sensor at the top of the interior container. The sen- sor must not come into contact with objects so that only the air temperature is measured.

Important!

4. Close the sensor cable opening at the back of the appliance with the sealant provided.

The condenser must be unscrewed to make the sensor cable opening accessible.

1. Unscrew condenser screws (6 pcs.) and fold out condenser at an angle.

Important!

Make sure that no pipes are bent.

2. Drill marked section at the back of appliance.

Important!

Only drill the outer wall of the housing.

Do not drill too far.

3. Pull out strain relief device (top left of interior container).

4. Feedsensorthroughopening and secure sensor cable with strain relief device.

Important!

Position the sensor at the top of the interior container. The sen- sor must not come into contact with objects so that only the air temperature is measured.

Important!

5. Close the sensor cable opening at the back of the appliance with the sealant provided.

6. Screw condenser back on.

20

Image 10
Contents 7082 Disposal notes Other featuresSafety instructions and warnings Description of appliance and equipmentConnecting to the mains DimensionsSetting up Safety lockCalling up the temperature history Switching the appliance on and offSetting the temperature Adjustable temperature rangeAlarm messages Adjusting the alarm parametersAudible warning signal Door open alarmExample of an alarm query Calibrating the control sensorChanging the network address Calibrating the product sensorActivating the sensor Cleaning Setting the real time clockResetting the parameters to factory settings Do not use steam cleaners because Risk of injury and damageMalfunctions External alarmFloating alarm output Shutting your appliance downRemove upper drawer before beginning work Opening for external temperature sensorModel LGUex Model LGex Make sure that no pipes are bentVeiligheidsslot Installation dimensions mm LGUexChanging over door hinges Version