Example of an alarm query
Situation: HACCP flashes in the display.
Display =
Display = | There has not been an alarm status with a | |
| too high or too low temperature. You must | |
| switch to display | . |
Display =
Press this button until appears in the display. Display = 1 power failure has occurred.
Display = |
|
Display = | Last power failure. |
Display = | Year 2010 |
Display = | Month 05 (May) |
Display = | Day 30 |
Display = | Hour 23 |
Display = | Minute 14 |
Display = | The power failure lasted 3 hours. |
Press + for 5 seconds. The display will read . The HACCP LED will now light up permanently.
The electronic control system is now ready for the next alarm.
Press for 5 seconds.
The electronic control system will switch back to normal operat- ing mode.
Calibrating the control sensor
temperature control)
Possible tolerances of the control sensor (the displayed tempera- ture compared to the actual interior temperature) can be offset with this function.
Press for 5 seconds. Display = Display =
Display =
Display = correction value set at the factory
Use buttons or to increase or decrease the correction value in 0.1°C increments.
Display = actual (corrected) interior temperature Display =
Press for 5 seconds.
The electronic control system will switch back to normal operat- ing mode.