Bosch Appliances installation manual Additional technical data, LC1-WC06E8

Page 22

22 en Technical Data

LC1 Modular Ceiling Loudspeaker Range

 

 

3.5

Additional technical data

 

3.5.1

LC1-WC06E8

 

 

 

 

62 mm (2.44 in)

 

 

 

 

 

 

220 mm (8.67 in)

 

23 mm (0.9 in)

39 mm (1.53 in)

 

 

Dimensions

 

 

 

 

 

Common

Common

4

 

Phase

6W

-W

 

Earth

3W

6W

 

 

 

1.5W

3W

 

 

 

0.75W

1.5W

 

 

 

-

0.75W

 

 

 

70V

100V

 

Circuit diagram

 

 

 

 

 

 

 

 

 

 

 

 

 

Octave band sensitivity

 

All measurements are done with a pink noise signal. The values are in dBSPL

 

 

 

125Hz

250Hz

500Hz

1000Hz

2000Hz

4000Hz

8000Hz

A-weighted

lin-weighted

 

 

Octave SPL 1W/1m

85.3

88.3

87.5

88.4

93.4

93.8

88.0

 

 

 

 

Total octave SPL 1W/1m

 

 

 

 

 

 

 

89.0

89.7

 

 

Total octave SPL Pmax/1m

 

 

 

 

 

 

 

106.2

107.1

 

 

 

 

 

 

 

 

 

 

 

 

 

Octave band opening angles

 

 

 

 

 

 

 

 

 

 

 

125Hz

250Hz

500Hz

1000Hz

2000Hz

4000Hz

8000Hz

 

 

 

 

Horizontal opening angle

180

180

180

180

180

75

96

 

 

 

 

Vertical opening angle

180

180

180

180

180

75

96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F.01U.076.021 V1.0 2012.04

Product Information & Installation Manual

Bosch Security Systems B.V.

Image 22
Contents LC1 Modular Ceiling Loudspeaker Range Page Table of Contents Housings LoudspeakersAccessories 2Installation 50 mm 12W 24W 2LC1-CMR/LC1-CBB Max mm 12W 24W 3LC1-MFD Max 12W 24W 4LC1-CSMB MIN / MAX LC1 MSK Technical Data ElectricalMechanical LC1-WC06E8Environmental conditions LC1-TB LC1-PIBStandards Additional technical data LC1-WC06E8Frequency response 2LC1-WM06E8 Bosch 3LC1-UM06E8 1000 10000 100000 Frequency HzFrequency reponse 4LC1-UM12E8 Frequency response 5LC1-UM24E8 125 250 500 1000 2000 4000 8000 EC declaration of conformity LC1-CBB, LC1-CSMB, LC1-MSKPage Bosch Security Systems B.V