Technical Data

This cooker is designed for use on either :-

NATURAL GAS (Cat I2H ) at 20mbar or

LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.

NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.

Country of Destination: GB

Gas

 

Electric

Natural Gas

20mbar

220 - 240V 50Hz

Butane

29mbar

 

Propane

37mbar

 

(See appliance data badge for test pressures)

Dimensions

Overall height including optional splashback

minimum 1060mm

maximum 1090mm

Overall height

minimum 893mm

maximum 920mm

Overall width

900mm See ‘Positioning of Cooker’

Overall depth

648mm

 

Space for fixing

See ‘Positioning of Cooker’

Minimum space above hotplate

650mm

 

Connections

 

Gas:

 

 

Electric

 

 

 

 

Rp 1/2 at rear right-hand side

220 - 240V 50Hz

 

 

Ratings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

 

L.P. Gas

 

 

 

 

 

 

 

 

Hotplate

 

 

Injector

 

 

Injector

 

Wok burner

3.5kW

 

internal 80

3.5kW (246g/h)

internal 54

 

 

external 129

external 77

 

 

 

 

 

 

 

Large Burner

3.0kW

 

134

3.0kW (210g/h)

87

 

Medium Burners

1.7kW

 

109

1.7kW (119g/h)

68

 

Small Burner

1.0kW

 

75

1.0kW (70g/h)

51

Main Oven

3.2kW

 

237

2.9kW (224g/h)

85

Grill

2.73kW

 

190

2.73kW (192g/h)

85

Gas burner inputs based on Gross Calorific Value

Tall Oven

Forced air convection

2.5kW

 

Energy efficiency class on a scale of A (more efficient) to G (less efficient)

B

Energy consumption based on standard load

0.95kWh

Usable volume (litres)

53

Size

Medium

Maximum total electrical load at 230V 2.6kW (approximate total including oven light, oven fan etc.)

37

Page 37
Image 37
Rangemaster 90 Gas manual Technical Data