Hoover PL74, PL73 manual Electrical Connection, GAS Connection, Gb Ie, Ie Gb, Injector GB IE

Page 4

ELECTRICAL CONNECTION

Check the data on the rating plate, located on the outside of the unit, to ensure that the supply and input voltage are suitable.

Before connection, check the earthing system.

By Law, this appliance must be earthed. If this regulation is not complied with, the Manufacturer will not be responsible for any damage caused to persons or property. If a plug is not already attached, fit a plug appropriate to the load indicated on the rating plate. The earth wire is coloured yellow/green. The plug should always be accessible.

Where the Hob is connected direct to the electricity supply, a circuit breaker must be fitted with at least a 3 mm contact spacing when in the open position.

If the power supply cord is damaged this is to be replaced by a qualified engineer so as to prevent any potential risk.

To prevent any potential damage to the hob please carry out the installation following this sequence:

GB IE

1/2 GAS CONICAL

The earth wire ( green a yellow coloured) must be at least 10 mm longer than the live and neutral wires.

The section of the cable used must be of the correct size in relation to the absorbed power of the hob.

Please check rating plate for the power details and ensure that the power supply cord is of the type H05RR-F, H05VV-F, H05V2V2-F.

A)As illustrated, as- semble parts in se- quence:

A)fixed pipe

B)washer

C)Elbow fitting with tapered thred connection

2)Tighten the joints with the Spanners, remembering to twist the pipes into position.

3)Attach fitting C to mains gas supply us- ing rigid copper pipe or flexible steel pipe.

MAINS

LIVE

L

 

 

 

 

BROWN WIRE

 

 

 

 

 

 

 

 

 

 

 

 

EARTH

 

 

 

 

 

 

 

 

 

SUPPLY

 

 

 

 

 

GREEN/YELLOW WIRE

POWER

NEUTRAL

N

 

 

 

 

BLUE WIRE

CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS CONNECTION

These instructions are for Fitters qualified for installation of equipment in line with the relevant national standard. All work must be carried out with the electricity supply dis- connected.

The rating plate on the hob shows the type of gas with which it is designed to be used. It is possible to use other types of gas after carrying out some simple modifications. (See the instructions in the following paragraphs).

connection to the mains gas supply or gas cylinder should be carried out according to the relevant national standards, after having checked that it is regulated for the type of gas with which it will be supplied. If it is not correctly regulated follow the instructions in the paragraph entitlet « Adaption for different types of gas» . For liquid gas (cylinder gas) use pressure regulators which comply with the relevant national standards.

N.B.: for safe operation, economic use of energy and to ensure greater durability of the appliance, make sure that the supply pressure conforms with the values shown in the table on page 44.

Use only pipes, washers and sealing washers which comply with the relevant national standards.

When connecting the hob to the gas supply via use of flexible hoses please ensure that the maximum distance covered by the hose does not exceed 2 metres.

N.B.: carry out a final check for leaks on the pipework using a soapy solution. Never use a flame. Also, make sure that the flexible pipe cannot come into con- tact with a moving part of the cabinet (eg, a drawer) and that it is not situated where it could be damaged.

IE GB

15

For some models a conic link is furnished to outfit for the installation in the countries whe- re this type of link is obligatory; in the following figures it is pointed out how to recognize the different types of links. In every case the cylindrical part of the link has to be connec- ted to the hob.

Fig. 5

CYLINDRICAL

CONICAL

ADAPTING THE HOB TO DIFFERENT TYPES OF GAS

To adapt the Hob for use with different types of gas, carry out the following instructions:

remove the grids and burners

insert on hexagonal spanner (7 mm) into the burner support (Fig. 6)

unscrew the injector and replace it with one suitable for the gas to be used (see Table of gas consumption)

INJECTOR

Fig. 6

16

GB IE

Image 4
Contents Piani Cottura Instructions for the Installer InstallationBuilt in Hobs GB IEFor U.K. only Instructions for the Installer Electrical Connection for U.K. onlyGAS Connection for U.K. only Suitable locationElectrical Connection GAS ConnectionGB IE IE GBUsing the GAS Burner General AdviceUSE of HOB Regulating the Minimum FlameMaintenance and Cleaning CoverAftercare It is important the Burners are replaced correctlyWeee

PL73, PL74 specifications

The Hoover PL74 and PL73 are advanced vacuum cleaner models that exemplify Hoover's commitment to blending power, efficiency, and user-friendly design. These models are tailored for those seeking a reliable cleaning solution without compromising on performance or convenience.

One of the standout features of the Hoover PL74 and PL73 is their impressive suction power, enabled by Hoover’s innovative motor technology. This technology not only ensures deep cleaning across various surfaces, including carpets and hard floors, but also enhances the longevity and durability of the vacuum. The models employ a cyclonic filtration system which separates dirt from air, preventing clogging and maintaining suction strength over time.

Another key characteristic of the PL74 and PL73 is their lightweight design. Weighing significantly less than many comparable models, these vacuums provide unparalleled maneuverability. Users can easily carry them up and down stairs or around the home without experiencing fatigue. This is complemented by a user-friendly handle and a flexible hose that enhances reach, allowing for easy cleaning of hard-to-reach areas like under furniture and along edges.

The Hoover PL74 and PL73 also incorporate advanced filtration systems that capture allergens and fine dust particles, making them an excellent choice for allergy sufferers. The HEPA filters used in these models ensure that air expelled back into the environment is cleaner than the air taken in, promoting a healthier home atmosphere.

For added convenience, both models come equipped with a range of attachments, including a crevice tool, dusting brush, and upholstery nozzle. These attachments are beneficial for tailored cleaning tasks, from detailed cleaning of furniture and delicate surfaces to targeted suction in narrow spaces.

Ease of use is further enhanced by features such as a large dust bin that minimizes the frequency of emptying, LED indicators that signal when the dust bin is full, and an easy-to-use power control system that allows users to adjust suction power as needed.

In summary, the Hoover PL74 and PL73 vacuum cleaners combine powerful suction, lightweight design, and advanced filtration technologies to deliver outstanding cleaning performance. These features make them not only effective cleaning tools but also convenient and practical choices for modern homes. Whether tackling pet hair, allergens, or everyday dirt, these Hoover models stand out as reliable solutions for maintaining a clean and healthy living environment.