Trouble Shooting
The Refrigerator does not Work
Check that:
∙The mains switch in your home is on.
The Appliance does not Refrigerate Properly
Check that:
∙The door is shut properly and that the door seal is not damaged;
∙The thermostat temperature knob is on the correct setting;
∙The refrigerator has not been overfilled.
Food in the Refrigerator is too Cold
Check that:
∙The thermostat knob is on the correct setting.
The Motor Runs Continuously
Check whether:
∙The door is not closed properly or has been left open;
∙The room temperature is not too high.
The Appliance is Noisy
Check whether:
∙The appliance is perfectly level;
∙The appliance has been installed between cabinets or other objects that vibrate or make noise.
There is Water on the Bottom of the Refrigerator
Check whether:
∙The defrost drain is clogged.
Remember that the refrigerant in the cooling circuit causes a slight bubbling sound, even when the compressor is not running (this is quite normal).
If after all the checks, the appliance still does not operate or the problem persists, call the nearest Service Centre and inform them of: the type of problem, the abbreviation of the model name (Mod.) and the relative numbers (S/N) written on the rating plate located at the bottom left next to the vegetable crisper (see examples in the figures below).
Mod. RG 2330 |
|
|
|
|
| TI |
| Cod. 93139180000 | S/N 704211801 | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
220 - 240 V- |
| 50 Hz |
| 150 W |
|
|
|
|
| W | Fuse | A |
|
| Max 15 w | |||||||||
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Class |
Total | 340 |
|
|
|
| 75 |
|
|
|
|
|
|
|
|
|
|
| Freez. | Capac | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
Gross |
|
|
| Gross |
|
| Net |
|
|
| Gross |
| Poder de Cong | Clase N | ||||||||||
Bruto |
|
|
| Bruto |
| Util |
|
|
| Bruto |
| kg/24 h 4,0 | Classe | |||||||||||
Brut |
|
|
| Brut |
|
|
|
| Utile |
|
|
| Brut |
| ||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||
Compr. |
| R 134 a |
|
| Test | Pressure |
|
|
|
|
|
|
|
|
|
| ||||||||
Syst. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Kompr. |
| kg 0,090 |
|
|
|
|
|
|
|
|
|
|
|
|
Made in Italy 13918
|
|
|
| RG 1145 | WEU 47133980001 | |||
MADE IN ITALY | S/N | 704045585 |
|
|
| |||
VOL. BRUT | l. |
| REFRIGERATEUR l. | CONGELATEUR | l. | |||
GROSS VOL. | 135 |
| REFRIGERATOR | 225 | FREEZER |
| ||
VOL. BRUTO | cu. fl. |
| FRIGORIFICO | cu. fl. | CONGELADOR | cu. fl. | ||
SYSTEME A COMPRESSION | REFRIGERATEUR R134 A | CONGELATEUR R134 A | ||||||
SYSTEM | K |
| REFRIGERATOR | 0,080 | FREEZER | kg | ||
SISTEMA |
| FRIGORIFICO | kg. | CONGELADOR | ||||
POUVOIR DE CONGEL. kg/24h | FUSE LINK | HZ | W | CLASSE | ||||
FREEZING CAPACITY |
|
| A | V | 50 | 110 | CLASS | |
PODER DE CONGELACION |
| CLASEN |
Never call on unauthorized technicians and always refuse spare parts which are not originals.