Burner and Nozzle Specifications
GB |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Table 1 |
|
|
|
|
| Liquid Gas |
| Natural Gas | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Burner | Diameter | Thermal Power | Nozzle | Flow* |
| Nozzle |
| Flow* | ||||
|
| (mm) | kW (p.c.s.*) | 1/100 | 1/100 | g/h |
| 1/100 |
| l/h | |||
|
|
| Nominal |
| Reduced | (mm) | (mm) | *** |
| ** | (mm) |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fast | 100 | 3.00 |
| 0.7 | 41 | 87 | 218 |
| 214 | 128 |
| 286 |
| (Large)(R) |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Semi Fast | 75 | 1.90 |
| 0.4 | 30 | 70 | 138 |
| 136 | 104 |
| 181 |
| (Medium)(S) |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Auxiliary | 51 | 1.00 |
| 0.4 | 30 | 52 | 73 |
| 71 | 76 |
| 95 |
| (Small)(A) |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Supply | Nominal (mbar) |
|
|
| 37 |
| 20 | |||||
| Minimum (mbar) |
|
| 20 |
| 25 |
| 17 | |||||
| Pressures |
|
|
|
| ||||||||
| Maximum (mbar) |
|
| 35 |
| 45 |
| 25 | |||||
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*At 15°C and 1013 mbar- dry gas
** | Propane | P.C.S. = 50,37 | MJ/Kg |
*** | Butane | P.C.S. = 49,47 | MJ/Kg |
| Natural | P.C.S. = 37,78 | MJ/m3 |
SS
A R
KD3G11/G
KD3G11S/G
6