MX250 series Microprocessor Controller

LEDs are used in a recognizable line configuration for continuous monitoring of switch position. A new LCD display shows source availability, exercise time delay operation and system source condition. A new simplified adjustment is featured for voltage, frequency and time delay settings.

The control operates off a close differential 3 phase under-voltage sensing of source 1, factory standard setting 90% pickup, 80% dropout; under- frequency sensing of source 1 factory setting 95% pickup; voltage and frequency sensing of source 2, factory standard setting 90% pickup voltage, 95% pickup frequency. All factory settings are operator adjustable (see table below).

A test is standard (fast test/load/no load) to simulate source 1 failure - automatically bypassed should source 2 fail.

More Enhanced Features

Available in ALL transfer modes:

~Open, Delayed & Bypass

~Closed (with newly integrated transition control)

User-friendly programmable engine exerciser, used for the engine generator with or without load, at ANY interval in a one-year period

Operating voltages available in a single controller for most domestic and international applications

Real-time display of ATS status, including active timer(s)

Multiple levels of user-defined password protection

Serial communications allowing connectivity with other ATS's, paralleling switchgear, and SCADA systems

Time-tested synchronous logic automatically measures phase angle and frequency allowing disturbance-free transfer

Unsurpassed statistical ATS/System monitoring available in real-time

T3/W3 elevator pre-signal. Automatically bypassed if the selected source fails, minimizing time an elevator is without power

Universal Motor Disconnect (UMD) sends

a pre-signal, post-signal or both to any motor control center. Not bypassed in an outage, the UMD ensures safety in the event of a single phase loss

Voltage unbalance detection standard

Extensive 2/5/10 Warranty

Performance Features

UL, CSA and IEC listed

Ringing wave immunity per IEEE 472 (ANSI C37.90A)

Condusted and Radiated Emissions per EN55022 Class B (CISPR 11) (Exceeds EN55011 & MILSTD 461 Class 3)

ESD Immunity test per EN61000-4-2 (Level 4)

Radiated RF, electromagnetic field immunity test per EN61000-4-3 (ENV50140) 10v/m

Electrical fast transient/burst immunity test for EN61000-4-4

Surge immunity test per EN61000-4-5 IEEE C62.41 (1.2 x 50ms, 5 & 8 kV)

Conducted immunity test per EN61000-4-6 (ENV50141)

Voltage dips and interruption immunity EN61000-4-11

Technical Benefits

Separate line voltage components for controller isolation

Inputs optoisolated for high electrical immunity to transients and noise

Built-in electrical operator protection

Simplified maintenance – major components are easily replaceable

Close differential under-voltage sensing of the normal source

Voltage and frequency sensing of the emergency source (all settings are adjustable)

Page 3 PB-5066

Image 3
Contents Quality System ISO 9001 Registered Product BulletinZTS Series Automatic Transfer Switches Technical Benefits More Enhanced FeaturesMX250 series Microprocessor Controller Available in ALL transfer modesMstds Mexes Mcons Msens Mspes Mpsgs ZTS Series Accessory Group MatrixZTS Series Accessory Definitions R15/R15D M85M86 R1-1/R1-3Circuit Amps ZTS Series Withstand RatingsRated for Total Systems or Motor Loads ZTS Model Transfer Switches Ampere ZTS Series Ordering Information