Master Bilt IM-23GB manual Operation, HOW to Change SET Points

Page 8

OPERATION

Fan The fan will run constantly except when a defrost is initiated, or when the evaporator temp is above 35oF. When in defrost mode the fan is off until the end of the defrost and the 2 minute drip time has passed. There is 2 minutes delay after a defrost before the fan comes on. The difference of the evaporator and room temperature of more than 9oF will override the fan delay. FAN LED indicator is flashing during 2 minutes drip period.

Defrost The control uses time defrosts with four defrost per day for oil return safety. The defrost timer begins counting on power up. For example, if a defrost is desired at 12 am, 6 am, 12m, and 6 pm then power up the unit at any of those four times.

MANUAL DEFROST

1.Push this DEFROSTUP/DEFROST” key for more than 5 seconds and a manual defrost will start, if the conditions are correct, the led DEF will light up and the instrument will carry out a defrosting cycle.

2. While in defrost, push and hold the DEFROST key for more than 5 seconds and the controller will end the defrost cycle. The controller will then enter drip mode for 2 minutes. The DEF led is flashing in drip mode.

HOW TO CHANGE SET POINTS

1.Press the P until sp-1 is displayed.

2.Push UP ▲ or DOWN▼ arrows to change the value.

3.To Exit: Press SET + UP ▲ or wait 20 seconds without pressing a key.

NOTE 1: The set value is stored even when the procedure is exited by waiting the time-out to expire.

NOTE 2: Master-Bilt’s SETPOINT is set at a recommended 20°F at the factory.

NOTE 3: If power is turned off to the unit, the set point returns to factory set value.

8

Image 8
Contents IM-23GB Page Table of Contents Introduction Store ConditionsGeneral Instructions Mechanical MASTER-BILT Electronic Refrigeration Control TLY-25Electrical General DescriptionMICROPROCESSOR-BASED Digital Electronic Freezer Controller 11 12 13 7HOW to Change SET Points OperationList of Parameters Alarm SignalsOther Signals Service Instructions Electrical ConnectionsTrouble Shooting Check ListCabinet Cleaning Procedures ICE Merchandiser Monthly ChecklistParts List Part DescriptionSale and Disposal Owner Responsibility