Norcold 963, 983, 962, 982 manual Refrigerator Failure, Maintenance Requirements Important Notice

Page 11

 

Fault external to refrigerator controls

Check: DC supply to refrigerator (10.5 VDC min.)

A7

Battery charging equipment or converter

DC input voltage too low

DC connection to the refrigerator

 

 

 

Consult your dealer or a Norcold Service Center

 

 

 

 

Fault external to refrigerator controls

Check: Battery(s) supplying DC to refrigerator (15.4 VDC max.)

A8

Battery charging equipment or converter

DC input voltage too high

DC connection to the refrigerator

 

 

 

Consult your dealer or a Norcold Service Center

 

 

 

C1

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

C2

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

C3

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

C4

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

 

 

Not owner serviceable

C5

Fault within refrigerator controls

Temporary operating mode; read "Back-Up Operating System" - page 9

"Back-Up Operating System Mode"

Seek service as soon as practical

 

 

 

Consult your dealer or a Norcold Service Center

 

 

 

C6

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

C7

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

C8

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

C9

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

D1

Fault within refrigerator controls

Not owner serviceable; Consult your dealer or a Norcold Service Center

 

 

 

 

 

 

Refrigerator Failure

Failure of refrigeration does not necessarily indicate that the cooling system is defective. Other factors governing its operation must be checked.

If a diagnostic code appears, refer to "Diagnostic Codes and Their Meanings" on page 10. If the refrigerator is operating on gas and a loss of cooling is noticed, switch the refrigerator to the AC mode of operation (see Start-Up Instructions on pages 8 and 9). If the refrigerator has been operating on electric, switch to gas operation. After the refrigerator has been switched from one power source to the other allow several hours to assure the refrigerator is cycling properly. This will determine if a component failure in the electric or gas controls is causing the cooling fault. If no cooling is evident after eight hours (or overnight), the cause of failure may be the cooling unit. To determine the actual cause for failure, contact your dealer or a Norcold service center.

Diagnostics

Maintenance Requirements

Important Notice:

Read and understand this notice before removing this refrigerator, re-installing this refrigerator, or performing any maintenance on this refrigerator. Norcold will not accept responsibility for installation, adjustment, alteration, service, or maintenance performed by anyone other than a qualified dealer or Norcold service center. Costs or related consequential problems resulting from improper installation, adjustments, alteration, service, or maintenance are the refrigerator owner’s responsibility.

1.Leak test gas supply piping and fittings at least once a year. This procedure should only be performed by your dealer or a Norcold service center. These facilities are familiar with gas refrigerators and propane gas systems.

2.Check the main line gas pressure and adjust if necessary. The correct gas pressure is 11 inches water column. It is recommended that your dealer or a Norcold service center perform this task.

3.Clean the refrigerator’s burner and burner orifice. This procedure is required once a year minimum and should only be performed by your dealer or a Norcold service center.

4.Insure that the LP gas supply is Propane, not another fuel such as Butane or Butane mixtures. Question the facility in which you purchase your gas.

5.Check the burner flame appearance during gas operation. Inspect burner electrode assembly to insure it is secure to burner bracket.

11

Maintenance

Image 11
Contents Series Refrigerators Table of Contents Safety Awareness Model Number Serial Number About Your Refrigerator Door Handle Interior LightDoor Bin Slide About YourRefrigerator Door BinsRefrigerator Controls and Operating Instructions Adjustable ShelvesDoor Alarm Operating Controls Auto ModeManual Mode Backup Operating System BOSDiagnostic Codes and Their Meaning DiagnosticsDiagnostic Codes Refrigerator Failure Maintenance Requirements Important NoticeRefrigerator Storage MaintenanceRefrigerator Removal and Replacement Procedure for Cleaning the Cooling System FlueBody Burner Orifice Removal and CleaningFuse Replacement Procedure Wiring Limited TWO Year Warranty