Norcold 120x Ventilation Requirements, Assemble the Enclosure for the Refrigerator

Page 3

The installation must obey these standards and this “Installation Manual” for the NORCOLD limited warranty to be in effect. Installation must conform with local codes. In the absence of local codes, the installation must obey these standards:

In the United States:

-National Fuel Gas Code, ANSI Z223.1.

-Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 32-80.

-Standard for Recreational Vehicles, RVIA A119.2 latest edition.

-For installations which need an electric outlet that is energized by an external power source, the refrigerator must be electrically grounded as written in local or state codes, the National Electrical code, and ANSI/NFPA 70.

In Canada:

-Current CGA B149.1 and CGA B149.2 Installation code for Propane Appliances and Equipment.

-Current CSA Z240.4.2 Installation Requirement for Propane Appliances and Equipment in Recreational Vehicles.

-Current CSA Z240.6.2/C22.2 No. 148 Electrical Requirement for Recreational Vehicles.

-When installed, the refrigerator must be electrically grounded in accord with local or state codes, the Canadian Electrical Code C22.2. Parts 1 and 2.

All propane gas supply piping and fittings must obey local, state, and national codes about type and size. These components must also obey the current NFPA 501C section 2- 4, and in Canada with the current CAN 1-6.10 Standard.

Certified installation needs one lower intake vent and one upper exhaust vent. Install the vents exactly as written in this manual. Any other installation method voids both the certification and the factory warranty of the refrigerator.

The bottom of the opening for the lower intake vent, which is also the service access door, must be even with or immediately below the floor level. This allows any leaking propane gas to escape to the outside and not to collect at floor level.

CSA International certification allows the refrigerator to have zero (0) inch minimum clearance at the sides, rear, top, and bottom. While there are no maximum clearances specified for certification, the following maximum clearances are necessary for correct refrigerator performance:

Bottom

0 inch min.

0 inch max.

Each Side

0 inch min.

1/2 inch max.

Top

0 inch min.

1/4 inch max.

Rear

0 inch min.

1 inch max.

These clearances plus the lower and upper vents allow the natural air draft that is necessary for good refrigeration. Cooler air comes in through the lower vent, goes up around the refrigerator coils where it removes the excess heat from the refrigerator components, and goes out through the upper vent.

The refrigerator also has two thermostat controlled fans to move air across the cooling system. These fans turn on when the condenser fin temperature at the thermostat is about 130° F or higher and only when the refrigerator controls are on. These fans turn off when the condenser fin temperature at the thermo- stat is about 115° F or less. Even with these fans, if the air flow is blocked or decreased, the refrigerator will not cool correctly.

Each NORCOLD model is certified by CSA International for correct ventilation. Install only the certified vents that are listed in this manual.

Ventilation Requirements

WARNING: The completed installation must:

-Make sure there is sufficient intake of fresh air for combustion.

-Make sure the living space is completely isolated from the combustion system of the refrigerator.

-Make sure there is complete and unrestricted ventila- tion of the flue exhaust which, in gas mode, can produce carbon monoxide. The breathing of carbon monoxide fumes can cause dizziness, nausea, or in extreme cases, death.

-Make sure the refrigerator is completely isolated from its heat generating components through the correct use of baffles and panel construction.

Assemble the Enclosure for the Refrigerator

1.Make sure the enclosure is 63 1/4 inches high x 32 11/16 inches wide x 24 inches deep.

2.Make sure the floor is solid and level:

-The floor must be metal or a wood panel and extend the full width and depth of the enclosure.

-The floor must be able to support the weight of the refrigera- tor and its contents.

3.Make sure there are no adjacent heat sources such as a furnace vent, a hot water heater vent, etc.

Installation Manual 3

Image 3
Contents Installation Manual Certification and Code Requirements Table of ContentsSafety Awareness Safety InstructionsAssemble the Enclosure for the Refrigerator Ventilation RequirementsCertified Vent RO Height Install the Lower and Upper VentsInstallation Manual Install Decorative Door Panels Connect the water supply line Connect the Propane Gas Components Ignition and Start Up Ignition and start up in Automatic ModeFault Codes Page Page Page Page Page Page Art01590
Related manuals
Manual 18 pages 14.54 Kb

120x specifications

The Norcold 120X is a prominent choice in the realm of absorption refrigerators, particularly favored in recreational vehicles (RVs), campers, and various off-grid applications. Boasting a range of features and technologies, the Norcold 120X presents a combination of efficiency, reliability, and convenience for users seeking a dependable cooling solution.

One of the standout features of the Norcold 120X is its dual-power capability. This versatile refrigerator can operate using both AC (alternating current) and DC (direct current) power, offering users flexibility depending on their energy source. Additionally, it can run on propane gas, which is ideal for off-grid scenarios where electric power may be limited. This multi-fuel functionality ensures that users can always rely on the Norcold 120X for consistent cooling, regardless of their location.

The Norcold 120X is designed with user convenience in mind. It features an intuitive control panel that allows users to easily monitor and adjust the temperature settings. With adjustable shelves and door bins, the interior layout can accommodate various food items and maximize storage efficiency. The refrigerator's sleek and compact design ensures it fits seamlessly into smaller spaces typically found in RVs or campers.

Another important characteristic of the Norcold 120X is its advanced absorption cooling technology. Utilizing a unique combination of ammonia and water as refrigerants, the absorption system produces minimal noise levels, making it a suitable choice for those seeking a quiet environment. Furthermore, the absence of mechanical compressors helps to reduce energy consumption, enhancing its overall efficiency.

In terms of insulation, the Norcold 120X boasts high-performance thermal insulation that enhances its cooling capabilities. This feature helps maintain internal temperatures even in hotter external environments, ensuring food and beverages remain fresh for extended periods.

Safety is also a priority with the Norcold 120X, which includes features such as a safety shut-off valve and a robust exterior casing to withstand the rigors of travel.

Overall, the Norcold 120X represents a fusion of innovative technology and practical design. With its reliability, energy efficiency, and user-friendly features, it undoubtedly stands out as a leading choice for those in need of a dependable refrigeration solution on the road.