The Most Energy Efficient Ventilation System.
The Avtec EcoArch combines both an economical and environmentally safe solution for the need for
The EcoArch ventilation system addresses the growing need to reduce the amount of conditioned air from a kitchen space. The combination of the patent pending arch top and the front mounted high velocity exhaust slot reduces the amount of exhausted CFM by 45% compared to traditional CFM rates. This translates into an annual electric and gas savings
of up to 40%.
Now that’s maximizing your energy and cost savings!
The Avtec EcoArch 2000 Series
Model Number1 | Hood Section Dimensions2 | Application | CFM/Ft3 | |
|
|
|
| |
Available length of 48” to 192” | 600˚F | 150 | ||
x 30” high | ||||
|
|
| ||
|
|
|
| |
Available length of 48” to 192” | 400˚F | 130 | ||
x 30” high | ||||
|
|
| ||
|
|
|
|
1 DD = Depth in inches, LLL=Length in inches, 30=Height in inches. Example:
2 For hood lengths longer than 192”, multiple sections can be grouped together. 3 Minimum CFM may vary based on cooking equipment application.
Constructed of High Grade
Up to 40% Annual Energy Savings
Using Exclusive Design Features
Exclusive Aerodynamic Arch – Dramatically reduces the amount of turbulence within the canopy reservoir. About 70% of the contaminated air is exhausted immediately out of the reservoir.
High Velocity Exhaust Slot – The higher rate of speed at the slot in addition to its location at the top of the canopy effectively removes the contaminated air working in conjunction with the arch top.
Easier and Safer Removal of Filter Medium
Unlike tradition rear filter locations, EcoArch exhaust plenum and filters are located in the front of the hood eliminating the need to climb on top of cooking equipment for daily removal and cleaning.
Recessed Fluorescent Light Fixtures
EcoArch comes standard with recessed fluorescent light fixtures to maximize light foot candles at the cooking surfaces with the least amount of energy consumption.
Sample Energy Savings
150 cfm/ft (EcoArch) vs. 250 cfm/ft (traditional unit)
12’ Hood, 400°F, Gas & Electric, Based on 2006 Utility Rates
Location | cfm/ft | Annual Gas | Annual Electric | Total Energy Annually | Savings % |
|
|
|
|
|
|
New York, NY | 250 | $5425 | $1364 | $6789 |
|
|
|
|
|
|
|
New York, NY | 150 | $3255 | $828 | $4083 |
|
|
|
|
|
|
|
Total Savings |
| $2170 | $536 | $2706 | 40% |
|
|
|
|
|
|
Atlanta, GA | 250 | $3728 | $943 | $4671 |
|
|
|
|
|
|
|
Atlanta, GA | 150 | $2237 | $571 | $2808 |
|
|
|
|
|
|
|
Total Savings |
| $1491 | $371 | $1863 | 40% |
|
|
|
|
|
|