Vinotemp VINO-6500SSR, VINO-2500SSR manual Use of the adjustable low pressure control if applicable

Page 6

8.Use of the adjustable low pressure control (if applicable)

Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig

It may need to adjust the setting in the field to get the right cycle time.

Fig. 2.6 Adjustable Pressure Control

9. Condensing Unit Troubleshooting

Unit not running

a.

Incorrect power supply

a.

Check for proper voltage

b.

Incorrect or loose wirings

b.

Check all wirings and connections

c.

Failed components

c.

Check start relay, start capacitor, overload

 

 

 

protector, compressor.

d.

Liquid refrigerant in the compressor

d.

Call service for OEM information

 

 

e.

Check for system restriction or low

e.

Low pressure switch shutting down the system

 

refrigerant

- 5 -

Image 6
Contents VINO-2500SSR VINO-4500SSR VINO-6500SSR Condensing UnitEvaporator Unit Air SensorRefrigeration Piping and Charging Pressure, Superheat and Subcooling Readings Valve OperationVINO2500-4500SSR Electrical Wiring Diagram Vtstat VINO2500-4500SSR Wiring Diagram Digital ControllerVINO6500SSR Electrical Wiring Diagram Vtstat Use of the adjustable low pressure control if applicable