Vinotemp VINO-2500SSR, VINO-6500SSR Pressure, Superheat and Subcooling Readings, Valve Operation

Page 3

5. Pressure, Superheat and Subcooling Readings

NOTES: THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ PROPERLY.

 

Complaint

 

 

Possible Causes

 

a.

High suction pressure and low head pressure

a.

Compressor may be bad

 

b.

High suction pressure and low head pressure

b.

Expansion valve opened, too

 

Low superheat and low subcooling

 

much oil

 

 

 

 

c.

High suction pressure and high head pressure

c.

Overcharge

 

 

 

 

 

Low superheat and high subcooling

d.

Non-condensable gas

 

d.

High to normal suction pressure and high head pressure

 

 

Low subcooling

e.

Air

restricted,

dirty

condenser,

e.

High suction pressure and high head pressure

 

Low subcooling

 

bad condenser fans

 

 

f.

High suction pressure and high head pressure

f.

High

room

temperature,

high

 

High superheat

 

evaporator load

 

 

 

g.

Low suction pressure and low head pressure

g.

Undercharge

 

 

 

 

 

High superheat and low subcooling

h.

Liquid

line

 

restricted

after

h.

Low suction pressure and low to normal head pressure

 

 

High superheat and high subcooling

 

receiver,

solenoid

valve

 

 

 

restricted

 

 

 

 

i.

Low suction pressure and low head pressure

i.

Suction line restricted

 

 

Low subcooling

j.

Air

restricted

at

evaporator,

j.

Low suction pressure and low head pressure

 

Low superheat and low subcooling

 

evaporator iced

 

 

 

k.

Low suction pressure and low to normal head pressure

k.

Evaporator restricted

 

 

 

High superheat and normal to high subcooling

l.

Expansion valve restricted

 

l.

Low suction pressure and normal head pressure

 

 

High superheat and normal subcooling

m. Both evaporator and condenser

m. Low suction pressure and high head pressure

 

High superheat and high subcooling

 

restricted

 

 

 

 

n.

Low suction pressure and high head pressure

n.

Liquid

line

restricted before

 

High superheat and high subcooling

 

receiver

 

 

 

 

o. low to normal suction pressure and high head pressure

o.

Condenser restricted

 

 

 

High to normal superheat and high subcooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Valve Operation

SPINDLE BACK POSITION SPINDLE FRONT POSITION SPINDLE MIDDLE POSITION

Fig. 2.1 Valve Operation

- 2 -

Image 3
Contents Condensing Unit VINO-2500SSR VINO-4500SSR VINO-6500SSREvaporator Unit Air SensorRefrigeration Piping and Charging Valve Operation Pressure, Superheat and Subcooling ReadingsVINO2500-4500SSR Wiring Diagram Digital Controller VINO2500-4500SSR Electrical Wiring Diagram VtstatVINO6500SSR Electrical Wiring Diagram Vtstat Use of the adjustable low pressure control if applicable