U-Line CO75, CO29 manual Condenser Cleaning, Interval Every Three Months

Page 11

Condenser Cleaning

Interval - Every Three Months

To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.

WARNING

Disconnect electric power to the unit before cleaning the condenser.

WARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

IMPORTANT

DO NOT use any type of cleaner on the condenser unit.

CO29 Condenser:

1. Disconnect power to the unit.

2

1

ULIN_0197_A

Figure 8

2.Remove the control knob (Figure 8, 1) by pulling it straight out, away from grille.

3.Remove two screws from grille (Figure 8, 2) and save.

4.Remove grille and grille cap from unit.

1

ULIN_0153_A

Figure 9

5.Clean the condenser coil (Figure 9, 1) using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

 

2

1

ULIN_0198_A

Figure 10

6.Make sure grille cap is behind grille in slots provided in grille (Figure 10, 1) before attaching grille to unit, and secure but do not overtighten both grille screws (Figure 10, 2).

7.Reinstall the control knob (Figure 8, 1).

8.Reconnect power to the unit.

CO75 condenser:

1. Disconnect power to the unit.

1

2

 

ULIN_0227_A

Figure 11

2.Remove control knob by pulling it straight out, away from grille (Figure 11, 1).

3.Loosen and remove screw (Figure 11, 2).

4.Tilt top of grille forward and remove.

1

ULIN_0226_A

Figure 12

5.Clean condenser coil (Figure 12, 1) using a soft brush with a “combing” action or vacuum cleaner. Do not touch condenser coil.

CO29, CO75

11

Image 11
Contents CO29 CO75 Use and Care GuideIntroduction Warranty RegistrationPlease Record Your Model Information Table of Contents This page intentionally left blank CO29, CO75 Safety Precautions Safety Alert DefinitionsGeneral Precautions Operation Product FeaturesOrigins Ice Maker/Refrigerator Models CO29, CO75 Initial StartupIce Maker Temperature ControlChecking Product Temperature Adjusting TemperatureStorage, Vacation, Moving Normal Operating SoundsOutdoor, Marine and RV Usage Interior Cleaning As Required General CleaningCleaning and Maintenance Exterior Cleaning As RequiredDefrosting MaintenanceInterval Every Three Months Condenser CleaningInlet Screen Interval Every Twelve Months Ice Maker MaintenanceIce Cube Thickness Adjustment Interval As Required Leveling Door Alignment Check and AdjustmentCO29 Door ReversalInvert CO75 Glass Shelf Removal/Installation Service Before Calling for ServiceIf Service is Required Replacement PartsTroubleshooting What to check when problems occur Troubleshooting GuideThis page intentionally left blank CO29, CO75 This page intentionally left blank CO29, CO75 This page intentionally left blank CO29, CO75 Line Corporation Limited Warranty For General Inquiries For Service and Parts Assistance