Conversion Kit
1) |
Check that the main gas supply line to the cooktop is shut off and that the power supply cord is disconnected.
2)
Remove access cap “A” by using a screwdriver or a quarter, turning the access cap
The regulator must be checked at a minimum water column of 1 inch (2.5 cm) above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:
-NATURAL GAS: Set pressure at 6” W.C. Supply pressure of 3 1/2” -
10 1/2” W.C. maximum;
- LP GAS: Set pressure at 10” W.C. Supply pressure of 8” - 13”
W.C. maximum.
The cooktop must be isolated from the gas supply piping system by closing the respective manual shut- off valve during any pressure testing of the gas supply piping system at test pressures equal to or greater than 1/2 psig (3.5 kPa).
4