Conversion Kit
5) |
Remove the screw A and push the support B fully down. Remove the nozzle C with a wrench and insert the suitable nozzle following the instructions in the tables referring to the type of gas to be used. The nozzle must not be tightened with a torque of more than 3 Nm. Return the support B to its original position, so that the nozzle C is perfectly covered.
Regulate the air flow by moving the Venturi pipe D until the distance “X” stated in point "5.5 Adjusting the primary air flow” is obtained and secure it with screw A. When theadjustments are complete, restore the seals with wax or a similar material.
6)
Referring to distance “X” in mm.
PTS605U – Natural gas
|
| Air Shutter |
|
| |
Left Central | 2/ ” - 7.0 mm | |
|
| 8 |
Central Front | 2/ ” - 7.0 mm | |
|
| 8 |
Central Rear | 2/ ” - 7.0 mm | |
|
| 8 |
Right Central | 3/ ” - 4.0 mm | |
|
| 16 |
| ||
PTS727U – Natural gas | ||
|
| Air Shutter |
|
|
|
Left | Inner | 3/8” - 10.0 mm |
Central | Outer | 3/8” - 10.0 mm |
Central Front | 2/ ” - 7.0 mm | |
|
| 8 |
Central Rear | 3/ ” - 7.0 mm | |
|
| 8 |
Right Front | 2/ ” - 7.0 mm | |
|
| 8 |
Right Rear | 3/ ” - 4.0 mm | |
|
| 16 |
PTS605U – LP
|
| Air Shutter |
| 1/2” - 12.0 mm | |
Left Central | ||
Central Front | 2/ ” - 7.0 mm | |
|
| 8 |
Central Rear | 2/ ” - 7.0 mm | |
|
| 8 |
Right Central | 3/8” - 10.0 mm | |
|
| |
| PTS727U– LP | |
|
| Air Shutter |
|
| 2/ ” - 7.0 mm |
Left | Inner | |
| 8 | |
Central | Outer | 1/2” - 12.0 mm |
Central Front | 2/ ” - 7.0 mm | |
|
| 8 |
Central Rear | 2/ ” - 7.0 mm | |
|
| 8 |
Right Front | 2/ ” - 7.0 mm | |
|
| 8 |
Right Rear | 3/8” - 10.0 mm |
| After carrying out the above adjustments, remount in reverse order to the instructions given in point “3”. |
7) | Caution: refit all flame caps in the same points from which they were removed. In fact, the flame cap |
| positions cannot be changed. After refitting them, ensure that they are perfectly positioned and that there |
| is no clearance between the cooktop and the flame caps. |
| FIRE HAZARD |
WARNING | - Use a soapy solution to check for proper tightness. |
- Never test for gas leaks with a match or other flames.
-Failure to follow this instruction can result in death or fire.
7