Smeg KR37X manual Installation, Wall drilling and bracket fixing

Page 6
INSTALLATION

INSTALLATION

Wall drilling and bracket fixing

 

100

100

 

 

170

 

175

 

11

 

390

 

 

12a

 

 

1240

100

100

 

1050

When installing the hood in recycling version it has to be taken into consideration that space re- maining between the hood and the upper limit (ceiling or self) is at least 8-10 cm.

On the wall, draw:

a Vertical line up to the ceiling or upper limit, at the centre of the area in which the hood is to be fitted;

a Horizontal line at a minimum of 1050 mm above the Cooker Top; .

As indicated, mark a reference point at 100 mm to the right of the vertical reference line.

Repeat this operation on the other side, checking that the two marks are level.

As indicated, mark a reference point at 390 mm above the horizontal reference line, and at 100 mm to the right of the vertical reference line.

Repeat this operation on the other side, checking that the two marks are level.

Drill at the points marked, using a ø 10 mm drill bit.

Insert the plugs 11 into the holes.

EN

 

1

 

15

Image 6
Contents Manual de Instruções Libretto di Istruzioni Instructions Manual Manuel d’InstructionsBedienungsanleitung Gebruiksaanwijzing Manual de instrucciones ɋɮɥɩɝɩɟɬɭɝɩ ɪɩ ɸɥɬɪɦɮɛɭɛɱɣɣSOMMAIRE INDICEINDEX INHALTSVERZEICHNISɎɅȻɂȻɍɀɆɗ INNEHÅLLINSTALLATION MAINTENANCERECOMMENDATIONS AND SUGGESTIONS CHARACTERISTICS DimensionsComponents INSTALLATION Wall drilling and bracket fixingAIR OUTLET ON THE BACK SIDE OF THE HOOD Hood support mountingAir outlet connection in the ducting version AIR OUTLET ON THE UPPER PART OF THE HOODDucting version Hood body mountingRECIRCULATION VERSION AIR OUTLET Recycling versionELECTRICAL CONNECTION Control panel ButtonFunction Cleaning the Filters MAINTENANCEResetting the alarm signal Metal grease filtersCHANGING THE ACTIVATED CHARCOAL FILTER Activating the alarm signalLIGHT REPLACEMENT Changing the Filter