Andrew ES76PK-1 installation instructions Step

Page 48

Step 4 Step 5

Step 6 Step 7

Step 8 Step 9

the installation/acceptance check off. If the readings differ by more than five percent, refer to appropriate troubleshooting information and perform applicable corrective action. Then take voltage readings off each of the three conductors; the readings should agree with each other within two percent. Turn the FEED CCW/OFF/CW switch to OFF.

Repeat preceding step (3) with the FEED CCW/OFF/CW switch in the alternate operat- ing position.

Turn the AZIMUTH EAST/WEST switch to either position and while the antenna is rotat- ing, carefully use a clamp on ammeter in accordance with the ammeter manufacturer’s instructions to take current readings off each of the three conductors (phases) connect- ed to the load side of the azimuth drive motor circuit breaker. Record the current draw in the equipment log and compare the readings to the reference values entered in the installation/acceptance check off. If the readings differ by more than five percent, refer to appropriate troubleshooting information and perform applicable corrective action. Then take voltage readings off each of the three conductors; the readings should agree with each other—within two percent. Turn the AZIMUTH switch to OFF.

Repeat steps (5) with the AZIMUTH EAST/WEST switch in the alternate operating posi- tion.

Turn the ELEVATION DOWN/UP switch to either position and while the antenna is rotat- ing, carefully use a clamp on ammeter in accordance with the ammeter manufacturer’s instructions to take current readings off each of the three conductors (phases) connect- ed to the load side of the elevation drive motor circuit breaker. Record the current draw in the equipment log and compare the readings to the reference values entered in the installation/acceptance check off. If the readings differ by more than five percent, refer to appropriate troubleshooting information and perform applicable corrective action. Then take voltage readings off each of the three conductors; the readings should agree with each other within two percent. Turn the ELEVATION switch to OFF.

Repeat steps (7) with the ELEVATION DOWN/UP switch in the alternate operating posi- tion.

If all voltage and current readings are within tolerance, close the local control/motor drive controller inner door and place the LOCAL/REMOTE switch in the REMOTE posi- tion to return antenna control to the studio. Then close and lock the outer local control/motor drive controller door.

50

Preventive Maintenance

Image 48
Contents Meter ESA Table of Contents Meter Earth Station Antenna IntroductionCustomer Service Center Proprietary Data Information and Assistance TechnicalOverview Content How to Use This ManualOverview Getting StartedRecommended Tools Tool Size QuantityGetting Started Returning Equipment Step Installation Procedures Overview Foundation PreparationTensioning Step 1b A-325 Tensioning For bolts over four diametersPedestal Ground Mount Assembly Installation Step Step Step Azimuth Jack Arm Installation Azimuth Jackscrew Assembly Step AZ Jack Pin 302383 4 Washer, 9997-188 8x1.0 Bolt Lockwasher Elevation Jackscrew Assembly Step Reflector Backstructure Assembly Step Step Step Step Typical 4 Places Then panel 3 and panel 4, and so on Step Reflector Alignment TheodoliteRib Panel Skin Refer to Figure Step Installation Procedures Installation Procedures Step Reflector Alignment Installation Procedures Installation Procedures Reflector to Ground Mount Assembly Step Subreflector Installation Step View A-ASubreflector Strut Support 300089 4 Places Adjustment Hardware, 3 Places Part Subreflector Centering Step Focusing Overview Acquiring a Satellite OperationStep Polarization at 45 degrees from Optimum Setting Maximizing Odd Transponders Subreflector Adjustment Survival Struts Overview General Cleaning Electrical Parts Preventive MaintenancePreventive Maintenance Antenna Preventive Maintenance Drive System Voltage Current Checks Step Step Preventive Maintenance Jackscrews/Motors Gear Motor/Housing Fill Drain Requirements Lubrication Chart Preventive Maintenance

ES76PK-1 specifications

The Andrew ES76PK-1 is a robust and highly efficient satellite communication antenna designed for both commercial and military applications. Its innovative design and advanced features make it an exceptional choice for high-performance connectivity.

One of the standout characteristics of the ES76PK-1 is its impressive gain. With a gain of approximately 76 dBi across a wide range of frequencies, it ensures optimal signal reception and transmission even in challenging environments. This high gain makes it ideal for applications requiring reliable long-distance communication, such as remote site operations or disaster recovery efforts.

The construction of the ES76PK-1 also prioritizes durability and resilience. Built with sturdy materials, this antenna is resistant to harsh weather conditions, including high winds, rain, and extreme temperatures. Its lightweight yet robust design allows for easier installation and maintenance, making it suitable for both fixed and mobile setups.

In terms of technology, the Andrew ES76PK-1 leverages advanced polarization techniques, which enhance its ability to transmit and receive signals effectively. This polarization capability ensures minimal signal degradation and interference, providing users with consistent and high-quality communication links. Furthermore, the antenna supports multiple frequency bands, thus offering flexibility in deployment and compatibility with various satellite systems.

The antenna's design incorporates a high level of precision engineering. This not only contributes to its excellent performance but also allows for fine azimuth and elevation adjustments. This feature is crucial in aligning the antenna accurately with satellite signals, further improving the quality of service for users.

Another key aspect of the Andrew ES76PK-1 is its compatibility with a range of RF systems. This versatility makes it a favored choice among service providers and enterprises looking to implement or upgrade their satellite communication infrastructure.

In summary, the Andrew ES76PK-1 stands out in the competitive landscape of satellite communication technologies. With its high gain, durable construction, advanced polarization, and compatibility with various systems, it meets the stringent demands of modern communication needs. This antenna is an excellent investment for anyone looking to achieve reliable and efficient satellite connectivity.