Whynter BWR-281DZ, BWR-461DZ instruction manual Problem Possible Cause Solutions

Page 18

PROBLEM

POSSIBLE CAUSE

 

SOLUTIONS

Display “E0”, “E1”.

“E0” indicates the communication error

Call for service

“E2”, “E3”, “E4”, “E5”

for 3 zone models

 

 

or “E7”

“E1” or “E2” indicates that the air

 

 

 

temperature sensor is failed

 

 

 

“E3” or “E4” indicates that the de-frost

 

 

 

sensor in the evaporator is failed

 

 

 

E5” indicates the defrost heater failure

 

 

 

E7” indicates the door switch failure

 

 

 

 

 

 

The alarm sounds

Door has been opened for more than 60

Close the door

and the

seconds

Do not open the door more often

temperature display

The appliance door being opened too

 

than necessary

flashes

often

Clear the obstructions and clean

 

The ventilation opening being covered

 

the dust

 

or too dusty

Leave the appliance to work for a

 

A lengthy interruption to the power

 

while until the set temperature has

 

supply

 

been reached.

 

A large amount of bottles has been

 

 

 

added to the unit

 

 

 

 

 

 

The icon “--” is lit up

The display temperature is out of the

Only temperatures within the

and flashing in the

range

 

range 16~99°F/-9~37°C the

temperature display.

 

 

appliance can display will be

 

 

 

shown. If the temperature is not

 

 

 

within this range, the icon “--” will

 

 

 

be displayed instead. That is nor-

 

 

 

mal

 

 

 

 

Page 18

Image 18
Contents MODEL# BWR-281DZ / BWR-461DZ Table of Contents Appliance Safety Important Safe GuidesPage Parts & Features Model BWR-281DZ Model BWR-461DZProduct Features Technical Data Model BWR-281DZ BWR-461DZBefore Using Your Appliance Important Safety InstructionsInstallation Instructions Installation of Your ApplianceElectrical Connection Installing Stainless Steel HandlesBUILT-IN Cabinet Instructions Extension CordReversing the Door Swing of Your Appliance Operating Your Appliance Door Alarm Setting the Temperature ControlTemperature Memory Function Temperature AlarmSabbath Mode Normal SoundsDefrosting and Ventilation Storage BWR-281DZ BWR-461DZ Door LockWine Shelves BWR-281DZ Wine Shelves BWR-461DZ Care and Maintenance Troubleshooting Guide Problem Possible Cause SolutionsProblem Possible Cause Solutions ONE Year Limited Warranty