P L A N N I N G I N F O R M A T I O N
Although the
Allow the door(s) to open a minimum of 90˚ or you‘ll have problems removing drawers. With the door opening at 90˚, you may have to move drawers slightly to clear the door interior.
For corner installations, allow for a minimum 76 mm filler so that the door can open to 90˚. If you‘re using raised panels, consider using a wider filler.
When units are installed side by side, a filler strip is recommended. The width of this filler strip will vary depending on the configuration and panels you use.
Be sure to add the filler strip width to your finished rough opening dimension. In any installation of two units side by side without a filler strip, add an additional 13 mm to your combined numbers. This will allow for the proper width.
IMPORTANT NOTE: Refer to the
E L E C T R I C A L R E Q U I R E M E N T S
International models from the factory designed without a transformer require a 220/240 V AC, 50/60 Hz electrical supply, fused at the correct rating for the unit. If required by local or national codes, the power cord can be easily replaced using the power inlet device.
International models using a factory installed transformer require a 220/240 V AC, 50/60 Hz electrical supply, fused at the correct rating for the unit. These models will come equipped with Schuko power cords. The power cord may need to be replaced depending on local and national codes. The USA power cord that is supplied with the product must be disconnected with the appropriate transformer output to be connected in its place.
IMPORTANT NOTE: The electrical outlet must be grounded. The outlet must be flush with the back wall. Refer to the Installation Specifications illustration for your model for exact placement.
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
P L U M B I N G C O N S I D E R A T I O N S
For
6.35mm OD copper line to the house supply, being sure to use an easily accessible
Do not use
For
IMPORTANT NOTE: In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
IMPORTANT NOTE: A reverse osmosis system can be used with Models ICB648PRO and ICB648PROG, provided there is constant water pressure of 1.4 bar to 8.3 bar supplied to the unit at all times.
The water line should be routed up through the floor within 13 mm from the back wall and no higher than 76 mm off the floor. If you have to come through the wall, make sure the water line is no more than 76 mm from the floor.
Regardless of the routing, allow 1 m of excess copper tubing to remain outside the wall or floor for easy connection to the unit. Refer to Installa- tion Specification illustrations.
M O D E L O P T I O N S
Model I601R
914 mm
All Refrigerator
Model I601RG
914 mm
All Refrigerator with Glass Door
Model I601F
914mm
All Freezer
Model I611
762 mm
Model I611G
762 mm
Model I650
914 mm
Model I650G
914 mm
Model I661
914mm
Model I642
1067 mm
Model I685
1067 mm
Ice Water Dispensing
Model I632
1219 mm
Model I695
1219 mm
Ice Water Dispensing
Model ICB648PRO
1219 mm
Model ICB648PROG
1219 mm