Whirlpool W10533016A installation instructions Natural gas oven orifice spud stamped with

Page 18

To Convert Oven Burner

1.Open the oven door and remove oven racks, oven tray, and flame spreader and set aside.

2.Lift oven burner. The orifice spud is behind the oven burner air shutter.

A

B

A. Oven burner

B. Air shutter

3.Locate Natural gas orifice spud stamped “47” in the package containing literature supplied with the range.

4.Use a ³⁄₈" combination wrench and remove the LP gas orifice spud.

5.Install the number “47” LP gas spud.

A

A. Natural gas oven orifice spud stamped with “47”

IMPORTANT: Do not overtighten.

6.Place LP gas oven burner spud in plastic parts bag along with LP gas cooktop burner spuds for future use and keep with the bag containing literature.

7.Reinstall oven burner.

8.Reinstall oven racks, oven tray and flame spreader.

Complete Conversion

1.Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.

2.Turn the manual shutoff valve in the gas supply line to the open position.

3.Refer to “Check Operation of Cooktop Burners” in the “Electronic Ignition System” section for proper burner ignition, operation and burner flame adjustments.

IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner.

Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone is not as distinct as the inner cone. Natural gas flames do not have yellow tips.

4.Close the oven door and turn the knob to “OFF.”

5.Refer to the “Complete Installation” section to complete this procedure.

18

Image 18
Contents Installation Instructions 30 76.2 CM Freestanding GAS Ranges Range Safety Your safety and the safety of others are very importantAnti-Tip Bracket Range Foot Installation Requirements Tools and PartsLocation Requirements Mobile home installations require Mobile Home Additional Installation RequirementsProduct Dimensions Cabinet Dimensions Electrical RequirementsGas Supply Line Gas Supply RequirementsType of Gas Gas Pressure RegulatorGas Supply Pressure Testing Installation InstructionsInstall Anti-Tip Bracket Unpack RangeTypical flexible connection Make Gas ConnectionTypical rigid pipe connection Floor MountingVerify Anti-Tip Bracket Is Installed Engaged Complete ConnectionInstalling/Replacing the Battery Level RangeElectronic Ignition System Battery Status IndicatorInitial lighting and gas flame adjustments While a knob is Then Lite position, ifCheck Operation of Cooktop Burners If the low flame needs adjustingIf the flame needs adjusting Check Operation of Oven/Broil BurnerComplete Installation If you need Assistance or ServiceIf range does not operate, check the following GAS Conversions LP Gas ConversionTo Convert Gas Pressure Regulator To Convert Surface Burners Complete Conversion Natural Gas ConversionTo Convert Oven Burner Std Burner Natural gas oven orifice spud stamped with Page W10533016A