GAS CONVERSIONS

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer.

LP Gas Conversion

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

2.Unplug range or disconnect power.

3.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

4.Remove the cap from the gas pressure regulator using a flat-blade screwdriver.

A

A.Cap

5.Turn the cap over so the LP is visible.

A

A. Cap

6.Reinstall the cap.

To Convert Gas Pressure Regulator

1.Turn manual shutoff valve to the “closed” position.

B

A

C

A. To range

B. Manual shutoff valve “closed“ position

C. Gas supply line

12

Image 12
Contents Installation Instructions 30 76.2 CM Freestanding GAS Ranges Range Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsLocation Requirements Mobile Home Additional Installation Requirements Product Dimensions Cabinet DimensionsMobile home installations require Electrical Requirements Gas Supply RequirementsType of Gas Natural gasGas Supply Pressure Testing Gas Supply LineGas Pressure Regulator Burner Input RequirementsInstallation Instructions Install Anti-Tip BracketUnpack Range Make Gas Connection Typical rigid pipe connectionTypical flexible connection Verify Anti-Tip Bracket Location Level Range Complete Connection Initial lighting and gas flame adjustments If the low flame needs adjustingElectronic Ignition System Check Operation of Cooktop BurnersComplete Installation If the flame needs adjustingIf you need Assistance or Service If range does not operate, check the followingGAS Conversions LP Gas ConversionTo Convert Gas Pressure Regulator To Convert Surface Burners To Convert Oven BurnerComplete Conversion Natural Gas ConversionStd Burner W10032050B