5.Sanitize the inside of the hopper and agitator with a solution of 1/2 ounce of household bleach in 1 gallon of water. (200 PPM)

6.Replace the agitator disk. Sanitize as described in Step 5. Be sure the center screw is replaced and the screw is tight.

7.Remove Ice Chute cover as follows:

A.Flex sides outward to disengage lower pins.

B.Lift Ice Chute cover to disengage upper pins.

C.Lower Ice Chute cover down out of unit. Note: it may be helpful to twist cover slightly.

8.Clean the inside of the ice chute and ice chute cover with a mild detergent solution and rinse thoroughly to remove all traces of detergent.

9.Reverse steps above to reassemble ice chute.

10. Sanitize as described in Step 5.

91875

6

Image 8
Contents ICE/DISPENSER Table of Contents Safety Precautions General DescriptionInstallation Instructions Gate Restrictor PlateAdjustmentno TAG Mounting Templates Operating Instructions MaintenanceCleaning Instructions 91875 Troubleshooting Guide Agitator TurnsWiring Diagram Solenoid Assembly Exploded Assembly Upper Parts List Exploded View Upper Section and Parts List Exploded View Lower Section and Parts List Motor Assembly Detail and Parts List Warranty IMI Cornelius INC