Step Four
SReconnect all product tubing. Be sure the tapered white nylon washers are in place.
SRoute the tubing through the back hole of the panel and tie in place.
SApply the DANGER decal to the top of the control box.
SSnap the grommet and the snap bushing into the holes of the control box as shown.
SPlace the ice bank control in the control box with the capillary tube going through the grommet. Screw the ice bank control in place.
SRoute the agitator motor electrical leads and the electrical cord through the snap bushing.
SConnect all wiring as shown.
SWhen connecting ground leads, be sure to attach power cord ground lead first then apply a nut and tighten. Then apply the ground lead from the agita- tor motor and then the final nut. Tighten securely
Capillary Tube |
|
| Agitator Motor Wire |
Grommet | (smooth) |
|
Green Ground wire
Agitator Motor
Red
Jumper Wire
Black | Snap Bushing | |
Jumper Wire | ||
|
Agitator Motor
Wire (Ribbed)
Red Wire | Black Wire | White Wire | Green Ground Wire | |
Gray Power Cord | ||||
| ||||
| Gray Power Cord | Gray Power Cord Power Cord (Secure | ||
|
|
| first to Control box |
P/N 185211007 | 4 | 8/25/94 |