Cornelius 750 Pre-Mix manual 189159001

Page 3

E.Pull ice bank control sensing bulb up out of holder in product coil basket and lay off to one side. BE CAREFUL NOT TO KINK CAPILLARY TUBE.

F.Disconnect anode wire from evaporator tank, then remove anode from holder in product coil basket. Discard old anode.

Unit Without sealed evaporator tank.

G.Disconnect agitator motor power cord.

H.Pull ice bank control sensing bulb up out of holder in product coil basket and lay off to one side. BE CAREFUL NOT TO KINK CAPILLARY TUBE.

I.Disconnect anode wire from evaporator tank, then remove anode from holder in product coil basket. Discard old anode.

J.Remove two screws on each side securing agitator motor to evaporator tank.

4.Disconnect product lines from back of dispensing valves sleeves. MAKE SURE LINES ARE LABELED FOR IDENTIFICATION SO THAT THEY MAY BE RECONNECTED TO PROPER VALVES.

5.Remove shank nuts from back of dispensing valves sleeves. Remove valves and sleeves, spacers, plate, and plate gasket from unit.

6.Unit without sealed evaporator tank.

A.Pull unit product inlet lines up through unit cabinet far enough to allow product coil basket and agitator motor to be lifted up and out of evaporator tank.

B.Very carefully, lift product coil basket and agitator motor up out of evaporator tank and lay them off to one side.

7.Unit with sealed evaporator tank.

A.Very carefully, lift product coil basket up out of evaporator tank and lay them off to one side.

IMPORTANT: If evaporator tank has hole in it allowing water to leak to inside of unit, hole may be repaired by using locally procured two-part epoxy patch.

8.Facing front of unit (dispensing valve side), remove left and rear lower access grilles for access to refrig- eration system.

9.Remove drip tray from unit.

10.Remove four screws above and three screws below lower front access grille securing front panel to unit.

11.Remove three screws above and one screw below lower left access grille securing left-side panel to unit.

12.Remove five screws securing left (facing dispensing valve side of unit) side corner securing front and left-side panels together.

13.Pull left and front side panels apart in preparation to route new SUCTION LINE ASS’Y (item 1) copper lines from lower part of unit to inside of evaporator tank.

Removal of Refrigerant. In starting work, be advised that the following warnings, cautions and notes are directly applicable:

WARNING: to avoid possible fatal electric shock or serious injury, disconnect electrical power from the unit before starting kit installation.

WARNING: To avoid electrical shock even after electrical power has been disconnected from the Unit, discharge the start capacitor by momentarily touching both terminals at the same time using an insulated screwdriver.

3

189159001

Image 3
Contents Required Supplies and Equipment Important Only qualified Personnel should install this KitIntroduction Unpacking the KITDisassembly Required EquipmentName and Description Use 189159001 Parts Location Do not Vent Refrigerant to Atmosphere KIT InstallationDo not Vent Refrigerant to Atmosphere AssemblyLeak Check ChargingPonents do not Interfere with Condenser FAN Testing

750 Pre-Mix specifications

Cornelius 750 Pre-Mix is an advanced beverage dispensing solution designed for high-efficiency service in various commercial settings, including restaurants, bars, hotels, and event venues. This system represents the epitome of convenience and versatility, allowing establishments to serve a wide array of soft drinks with minimal hassle.

One of the standout features of the Cornelius 750 Pre-Mix is its compact design, which enables it to efficiently fit into tight spaces, a common challenge in many hospitality environments. The system is engineered to handle both carbonated and non-carbonated beverages, providing versatility in the types of drinks that can be served. Its ability to accommodate diverse beverage options makes it an appealing choice for businesses that want to offer a varied drink menu without the need for multiple machines.

The Cornelius 750 Pre-Mix utilizes cutting-edge technologies to ensure optimal performance. It incorporates advanced refrigeration techniques that maintain beverage freshness and quality. This system also includes a user-friendly interface and intuitive controls, allowing staff to operate and manage drinks with ease, thus enhancing operational efficiency during peak service hours.

One of the characteristic advantages of the Cornelius 750 Pre-Mix is its low-maintenance design. The system features robust components that require minimal upkeep, allowing operators to focus on service rather than repairs. Additionally, it is built with energy efficiency in mind, helping to reduce operating costs while minimizing the environmental footprint.

The construction of the Cornelius 750 Pre-Mix employs high-quality materials that ensure longevity and durability, making it a wise investment for any beverage-serving establishment. The design also prioritizes clean lines and aesthetic appeal, contributing to a professional look that complements any décor.

Overall, the Cornelius 750 Pre-Mix stands out as a reliable and efficient beverage dispensing solution that caters to the needs of modern commercial environments. With its combination of advanced technology, ease of use, and versatile beverage handling capabilities, it is an ideal choice for businesses looking to elevate their drink service experience while maintaining high standards of quality and efficiency.