Isotemp Laboratory and Chromatography Refrigerators | Page 8 of 12 |
|
|
Fluorescent Lamps
Convenience Outlet
(Chromatography Refrigerators Only)
Manual/Automatic Condenser Fan
Part Number: 104416
The interior lamp is controlled by a rocker switch on the header panel. This light may be operated any time the cabinet power is turned on at the keyed power switch. If the interior lamp fails, replace with the same size and wattage lamp. DO NOT USE REDUCED WATTAGE LAMPS. The reduced wattage lamps generally fail to light below 60 °F (15 °C).
Chromatography Refrigerators come equipped with a convenience outlet located in the center of the back wall. Model 172G’s (three doors) have two convenience outlets. The total power that can be supplied by the outlet (or outlets in
WARNING: The convenience outlet is LIVE at any time the unit is connected to an electrical power source, regardless of the position of the key switch.
A rocker switch located on the left side of the top of the inside of the chamber is used to operate the condenser fan automatically or manually. With the switch in the automatic position, the condenser fan operates with the compressor. In the manual position, the condenser fan operates continuously.
During times of high ambient relative humidity conditions, more water is condensed on the evaporator and directed to the condensate pan. The condenser fan will run continuously in the manual setting to better dispose of this water. At times of low relative humidity, the switch can be set to automatic.