Dacor MMD30S dimensions MMD24, MMD30 & MMDV30, Planning, Guide

Page 1

MMD24, MMD30 & MMDV30

Revised 24”, 30” Microwave In-A-Drawer

PLANNING

GUIDE

08/27/08

1/1

 

B

 

A

 

 

C

 

 

 

 

D

 

E

 

F

 

 

 

G

K

H

I

 

 

 

 

N

J

I

Q

 

 

L

 

 

 

 

 

M

 

 

 

 

O

 

P

 

 

NOTES:

1.All tolerances: +1/16”, -0, (+1.6mm, -0), unless otherwise stated.

2.Spacing between appliances and doors/drawers is minimum required to allow for ventilation and to prevent scraping. Additional space may be required for appearance.

48" (1219mm)

3-prong

120 Vac power cord

 

 

MMD24

 

MMD30, MMDV30

A.

6"

 

A.

6"

 

B.

Electrical outlet location

B.

Electrical outlet location

C.

Anti-Tip block

C.

Anti-Tip block

D.

5"

 

D.

5"

 

E.

3 1/2"

E.

3 1/2"

F.

4"

 

F.

4"

 

G.

22

1/4" opening

G.

28

1/2" opening

H.

14

3/16" to bottom of Anti-Tip

H.

14

3/4" to bottom of Anti-Tip

 

block

 

block

I.

Allow 7/8" minimum overlap

I.

Allow 3/4" minimum overlap

J.

23

1/2" minimum depth

J.

23

1/2" minimum depth

K.

Allow 3/16" minimum overlap

K.

Allow 1/4" minimum overlap

C

F

B A

G

I

D

H

L.

36" nominal countertop height

L.

36" nominal countertop height

M.

Allow 7/16" minimum overlap

M.

Allow 7/16" minimum overlap

N.

Floor must support 100 lbs.

N.

Floor must support 100 lbs.

 

minimum

 

minimum

O.19" to top of ￿oor (recommended) O. 19" to top of ￿oor (recommended)

P.

24" cabinet minimum

P.

30" cabinet minimum

Q.

15 3/16" ± 1/16" opening

Q.

15 3/16" ± 1/16" opening

NOTE: Open Top Cabinet illustrated

CUTOUT dimensions

(6")

Anti-Tip block

E

 

MMD24

MMD30, MMDV30

A.

21 19/32"

A.

28 5/16"

B.

4 11/16"

B.

4 11/16"

C.

1 23/32"

C.

2"

D.

23

3/8"

D.

23 3/8"

E.

23

13/16"

E.

30"

F.

15

5/8"

F.

15 5/8"

G.

15 1/16"

G.

15 1/16"

H.

1" door thickness

H.

1 1/4" door thickness

I.15" auto drawer opening I. 15 1/4" auto drawer opening

Power cord length: 48”

overall dimensions

electrical outlet location

aNTI-TIP BLOCK LOCATION

5"

 

ELECTRICAL UTILITY LOCATION

 

 

 

Approximate

Model No.

Dedicated Circuit Required

Total Connected Load

Shipping Weight

All Models

120 Vac, 60 Hz, 15 Amp

1.56 kW (13 Amp)

128 lbs.

(Breaker)

 

 

 

 

Electrical specifications

 

Web: http://www.Dacor.com

Specifications are subject to change without notice.

12.7

Corporate Phone: 800-793-0093

See installation instructions for additional details.

Image 1
Contents Planning MMD24, MMD30 & MMDV30Guide