5925 Heisley Road • Mentor, OH
Ovens |
|
|
|
Rev. 1 (4/08) | Page 7 of 10 |
|
|
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE, continued
PROBLEM | POSSIBLE CAUSE | SOLUTION | |||
| 1. | Fuse | 1. | Replace | |
| 2. | Control | 2. | Replace | |
Cabinet does not heat, or doesn’t heat | 3. | Sensor | 3. | Replace | |
properly | 4. | Heater contactor | 4. | Replace | |
| 5. | Loose wiring at heater contactor | 5. | Replace | |
| 6. | On/Off Switch | 6. | Replace | |
|
|
|
|
| |
| 1. | On/Off Switch | 1. | Replace | |
Blowers do not operate | 2. | Fuse | 2. | Replace | |
3. | Blower | 3. | Replace | ||
| |||||
| 4. | Control | 4. | Replace | |
|
|
|
|
| |
Heaters will not shut off | 1. | Control defective | 1. | Replace | |
|
|
|
|
| |
|
|
| 1. | Replace | |
Vent fan does not shut off | 1. | Vent fan timer defective | 2. | Wait until timer has timed out | |
2. | Vent fan timer has not timed out |
| (about 45 minutes after power | ||
|
| ||||
|
|
|
| switch is turned off) | |
|
|
|
|
| |
| 1. | Fuse | 1. | Replace | |
Vent fans do not operate (See Note) | 2. | Vent fan timer defective | 2. | Replace | |
| 3. | Vent fan defective | 3. | Replace | |
|
|
|
|
| |
Control will not switch from “Cook” to | 1. | Oven is in probe mode | 1. | Switch to timer mode | |
“Hold” (timed mode) | 2. | Control defective | 2. | Replace | |
|
|
|
|
| |
Control will not switch from “Cook” to | 1. | Oven in timer mode. | 1. | Switch to probe mode. | |
2. | Probe not pluged in. | 2. | Plug in probe. | ||
“Hold” (probe mode) | |||||
3. | Control defective. | 3. | Replace | ||
| |||||
|
|
|
|
| |
| 1. | Oven in timer mode. | 1. | Switch to probe mode. | |
Control will not switch to “Cook” (probe | 2. | Probe temperature setting lower than | 2. | Set probe temperature to desired | |
| probe temperature |
| temperature | ||
mode) |
|
| |||
3. | Probe not plugged in | 3. | Plug in probe | ||
| |||||
| 4. | Control defective. | 4. | Replace | |
|
|
|
|
|
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement of electrical components must be done by a qualified electrician.
Refer to our Service Agency list,
Call