Daewoo KOG-396T1S KOG-371R0S KOG-391R0S, KOG-371H0S, KOG-373R0S Interlock Mechanism and Adjustment

Page 44

INTERLOCK MECHANISM AND ADJUSTMENT

The door lock mechanism is a device which has been specially designed to completely eliminate microwave radiation when the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.

(1)Primary interlock switch

When the door is closed, the hook locks the oven door. If the door is not closed properly, the oven will not operate. When the door is closed, the hook pushes the button of the microswitch. Then the button of the primary interlock switch bring it under ON condition.

(2)Secondary interlock switch and interlock monitor switch

When the door is closed, the hook pushes the lock lever downward. The lock lever presses the button of the interlock minitor switch to bring it under NO condition and presses the button of the secondary interlock switch to bring it under ON condition.

ADJUSTMENT :

Interlock monitor switch

When the door is closed, the interlock monitor switch should be changed(NO condition) before other switches are closed.

When the door is opened, the interlock monitor switch should be changed(NC condition) after other switches are opened.

(3)Adjustment steps

a)Loosen the one mounting screw.

b)Adjust interlock switch assmbly position.

c)Make sure that lock lever moves smoothly after adjustment is completed.

d)Tighten completely one mounting screw.

NOTE : Microwave emission test should be performed after adjusting interlock mechanism. If the microwave emission exceed 4 mW/cm2, readjust interlock mechanism.

43

Image 44
Contents Microwave Oven Table of Contents For Safe Operation Safety and PrecautionsFor Safe Service Procedures Specifications ModelKOG-391G/H/R0S KOG-376T1S KOG-396T1SOuter Dimension External View465 360 Feature Diagram Heating Element Oven Cavity Sefety Interlock SystemKOG-376T1S, KOG-396T1S KOG-371R0S, KOG-391R0S KOG-374R0S KOG-375R0S KOG-373R0S, KOG-393R0S Control Panel KOG-371G0S, KOG-391G0SKOG-371H0S, KOG-391H0S KOG-376T1S, KOG-396T1S Grill/Combi Stop/Clear Stop/Clear Start/Easy Cook Auto cook Installation Earthing InstructionsWattage output chart Operation and FunctionsDisassembly and Assembly To remove door assembly To remove cabinetTo remove door parts REF. no Part Code Part Name Description QTY RemarkPage Frame Door ABS Page REF no Part Code Part Name Description ’TY Remark Decorator DOOR*TPage Screw Tapping T2SN TRS 4X16 Mfzn Page BARRIER-SCREEN*0 SAN Page To remove control panel parts CONTROL-PANEL ABS Control Panel Knob Volume Button Function Button Fuction *A High voltage circuit wiring To remove magnetron To remove high voltage capacitorTo remove wind guide assembly To remove H.V.transformerTo remove tray motor To remove heater assmblyTo remove heater parts Interlock Mechanism and Adjustment AdjustmentInterlock Mechanism and Adjustment Trouble Shooting Guide Check ResultCheck Check Result Cause Cause Remedy Measurement and Test ProcedureHeating time for power output Microwave Radiation Test High voltage transformer High voltage capacitorHigh voltage diode MagnetronWiring Diagram KOG-396T1S Printed Circuit Board KOG-371G/H0S, KOG-391G/H0S Low voltage transformer checkVoltage Check Key check point Check Point RemarkMesurement point Point State Relay 2 on 5VDC GND Relay 2 OFF Point State Relay 1 on 5VDC GNDPoint State Close GND Check no Hethod RemedyC.B. Circuit Diagram Name Symbol Specification Part Code ’TY C.B. Location noR15 6W 10K 5% Printed Circuit Board KOG-376T1S, KOG-396T1S Wave Form Remedy RemarkMesurement point 24VDC Point State Relay 3 on 5VDC GNDC.B. Circuit Diagram C.B. Location no KOG-396T1S Printed Circuit Board KOG-371R0S, KOG-391R0S Mesurement point Point State Relay 2 on 5VDC GND Relay 2 OFF C.B. Circuit Diagram Name Symbol Specification Part Code ’TY Remark J1~J17, SJ1 Circuit Check Procedure Printed Circuit Board KOG-374R0S, KOG-375R0SMesurement point Point State Relay 2 on 5VDC GND Relay 2 OFF C.B. Circuit Diagram Name Symbol Specification Part Code QTY Remark Printed Circuit Board KOG-373R0S, KOG-393R0S Mesurement point Point State Relay 2 on 5VDC GND Relay 2 OFF C.B. Circuit Diagram Wire Copper TIN Coating J3, J5~J10, SJ1 Exploded View and Parts List KOG-371G/H/R0S, KOG-391G/H/R0S Total AssemblyREF no Part Code Part Name Description QTY Foot KOR-86150S KOR-61150S Exploded View and Parts List KOG-376T1S, KOG-396T1S CONTROL-PANEL AS Special Screw TT3 TRS 4X8 FLG Mfzn KOG-396T1S Part Code Part Name Description Supply Remark Exploded View and Parts List KOG-374R0S Special Screw TT3 HEX 4X8 Mfzn Exploded View and Parts List KOG-375R0S KOG-375R0S Exploded View and Parts List KOG-373R0S, KOG-393R0S Heater AS Foot 100 101 Printed Date Dec