TROUBLESHOOTING
The Refrigerator Does Not Cool Properly
1.Burner jet clogged. Clean. See Section Maintenance & Service, Item 2. Periodic Maintenance, Paragraph E. Item
2.Check level of refrigerator.
3.Restriction in air flow across cooling unit.
4.Heavy frost
5.Flue baffle not inserted properly in flue tube.
6.Improperly set thermostat.
See paragraph on thermostat. In hot weather the setting should be closer to “MAX” than usual.
7.Burner dirty.
Clean. See Section Maintenance & Service, Item 2. Periodic Maintenance, Paragraph E. Item 7.
8LP gas pressure low at burner.
Set main regulator so pressure does not drop below 11 inches water column at pressure test port.
9Burner not located properly under flue tube. Relocate.
10Burner damaged
Replace.
11.Odors and fumes.
1.Dislocated burner.
2. Damaged burner.
3. Dirty flue tube.
SPARE PARTS
The following list is a list of commonly used parts which should be available, if required, from your Dometic Service Center.
Part No. | Description | |
200 74 | Jet, no. 58 | |
200 75 | Burner, (with electrode) | |
293 03 | Electrode | |
293 14 | Thermocouple | |
200 75 | Cover, (burner) | |
293 16 | Safety valve | |
200 71 | Thermostat | |
200 74 | Piezo igniter | |
293 26 | Baffle |
|
17 37 | Heater,325W,120V | |
293 21 | Lamp | cover |
293 25 | Door shelf | |
293 25 | Door shelf, 3 pieces | |
200 74 | Knob | thermostat |
200 74 | Knob | (On/Off) |
293 27 | Flap, base front |
Contact an authorized service center for parts and repairs as needed.
REFRIGERATOR DIMENSIONS
Overall dimensions in inches and (mm):
Model No. RGE 400
Height
W i d t h
D e p t h
Total refrigerator volume: 7.3 cu.ft.
F | 293 | 29 | 32 | 1 | 1 | I |
| |
|
|
|
|
| 1 2 0 V O L T S A C | |||
|
|
|
|
| ||||
|
|
|
|
|
| |||
|
|
|
|
| @ |
|
| |
|
|
|
|
|
| &FLOW/GREEN |
|
|
*HEATER
@ - T H E R M O S T A T @TERMINAL BLOCK
&%:RY BOX 6V