Dometic RMD 8551, RMD 8505, RMD 8501 Exhaust duct system, Installing L205 without mosquito net

Page 14

Installation

4.3.3Installing L205 (without mosquito net)

To install the ventilation grille, cut a rectangle width 451 mm x height 156 mm, in the outer wall of the vehicle (for position of the cuts, see Fig. 11,12).

1

Seal the mounting frame making it waterproof (does not apply for mounting frames with integral seal).

Fig. 21

2

Insert frame and screw into position.

Fig. 22

3

Insert ventilation grille.

Fig. 23

4

Lock ventilation grille.

Fig. 24

5

Insert winter cover.

Fig. 25

4.3Exhaust duct system

The exhaust gas duct system must be made in such a manner as to achieve a complete extrac- tion of combustion products to the outside of living space. The flue gas is vented directly through the upper grille. Do not use any kind of aluminium flue pipe to lead the flue gas out.

The T-piece (Fig. 26) must be trented towards the outer wall.

Fig. 26

CAUTION!

An installation other than described will reduce the cooling capacity and jeopardise the manufacturer's warranty/product liabi- lity.

14

Image 14
Contents Installation Instructions Dometic GmbH Der Steinwiese Siegen Table of Contents Introduction Guide to these installation instructionsGeneral Copyright protectionDeclaration of Conformity WarrantyLimitation of liability InformationUsers responsibility Safety instructionsApplication according to Regulations Working upon and checking the refrigeratorRefrigerator rating plate Description of modelModel identification Technical data Subject to technical changesSide installation Installation instructionsInstallation Rear installation Draught-proof installation Ventilation and air extraction of the refrigerator Installation of lower and upper ventilation grilles LS300 Installing roof exhaust R500 Installing the ventilation systemInstalling LS300 Installing L205 without mosquito net Exhaust duct systemSecuring the refrigerator Installation recessRecess dimensions Frameless decor panel Decor panel dimensions Decor panel with frameGas installation Mains connection Electrical installationBattery connection Cable cross sections and cable lengthsD+ S+ Terminal strip4 D+ and solar connection only for AES models Wiring diagram Wiring diagram RMD8xx1Wiring diagram RMD8xx5 Einbau Einbau Dometic GmbH Der Steinwiese Siegen