Ground lift Operation
Due to the variety of power sources available to the DJ, Stanton has included a ground lift switch to be used on the ST-
For best operation of the ground lift, the following rules should be applied
When third pin safety ground is used, set the ground lift switch to the lift position. This position will isolate the cartridge ground from connection to earth ground.
When third pin safety ground is unavailable, set the ground lift switch to the connected position. This will place the cartridge ground in connection with the chassis ground, but since third pin grounding is not used, the cartridge ground will not be in connection with earth.