Electric Built-in Ceramic Downdraft Cooktop
PRODUCT MODEL NUMBERS
GJD3044R
Electrical: A
OVERALL DIMENSIONS
| ||
(54.1 cm) | width | |
depth |
|
(74.6 mm) burner box depth
blower housing
depth
CABINET OPENING DIMENSIONS
Venting system: Use metal vent only.
Exception: Under a concrete slab, PVC may be used. Rigid metal vent is recommended. Do not use plastic or metal foil vent.
This downdraft cooktop is rated at 60 feet
(18.3 m) of straight vent or the equivalent.
If vent length is 10 feet (3 m) or less, 6" (15.2 cm) diameter round vent may be used. If vent length is more than 10 feet (3 m), use 6" (15.2 cm) diameter round or
Venting system must terminate to the outside.
Cooktop location should be away from strong draft areas, such as windows, doors and strong heating vents or fans.
All openings in the wall or floor where cooktop is to be installed must be sealed.
30" (76.2 cm) min - 30" (76.2 cm) model 36" (91.4 cm) min - 36" (91.4 cm) model when higher than 18" (45.7 cm)
See Note ** for
minimum clearances
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Minimum distance | Do Not seal |
| 21" (53.3 cm) |
| ||||||||||
to nearest combustible |
| opening depth |
| |||||||||||
vertical surface | cooktop to countertop. |
|
|
|
|
| ||||||||
extending 18" (45.7 cm) |
|
|
|
|
|
|
|
|
| |||||
above cooktop |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1" (25.4 mm) |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| cutout width |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Minimum base cabinet dimensions —
30" (76.2 cm) base cabinet width 24" (61 cm) base cabinet depth 25" (63.5 cm) countertop depth
Countertop opening dimensions that are shown must be used. Given dimensions are minimum clearances and provide required 0" (0 cm) clearance.
New installations — Follow minimum dimensions given.
Replacement installation — Be sure that front edge of cooktop is at least
If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet.
Exhaust Duct |
| ||
hole in rear or |
| ||
Cutout Locations | 17" | ||
side of cabinet | |||
|
| (43.2 cm) | |
|
| ||
30" (76.2 cm) cooktop |
|
| |
|
| ||
36" (91.4 cm) cooktop |
|
|
**Note: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and bottom of unprotected wood or sheet metal.
21" (53.3 cm) cutout depth
2" (5.1 cm) minimum space to front edge of countertop
| Countertop must be | |
Select required duct cutout | ||
supported within | ||
(see Page 4 for exhaust duct | 3" (7.6 cm) of cutout. | |
cutout location). |
|
Side clearance — 6" (15.2 cm) minimum clearance between side of cooktop and side wall is recommended for maximum ventilation performance.
Rear clearance — 3/4" (19.1 mm) clearance between rear edge of cooktop and rear wall is recommended.
Motor/blower clearance —
2" (51 mm) minimum clearance between motor and cabinet is required for proper cooling. 6"
(15.2 cm) clearance is recommended for servicing access.
countertop
5" (12.7 cm)
18"
(45.7 cm)
floor
11" (27.9 cm) | 8" (20.3 cm) |
Install rear wall junction box in shaded area. Darker area is preferred.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 8286553 |
Instructions packed with product. Specifications subject to change without notice. |