Whirlpool 9761893A Complete Installation, Typical flexible connection, Complete Connection

Page 7

IMPORTANT: All connections must be wrench-tightened. Do not make connections to the gas regulator too tight. Making the connections too tight may crack the regulator and cause a gas leak. Do not allow the regulator to turn on the pipe when tightening fittings.

Use only pipe-joint compound made for use with Natural and LP gas.

Do not use TEFLON®† tape. You will need to determine the fittings required depending on your installation.

3.Remove surface burner heads, caps and grates from parts package. Insert tab in burner head into notch in burner base. Place burner cap on burner head. Burner heads should be level when properly positioned. If burner heads are not properly positioned, surface burners may not light and continuous sparking may occur. Place burner grates over burners and caps.

A

Typical flexible connection

1.Apply pipe-joint compound made for use with LP gas to the larger thread ends of the flexible connector adapters (see B and F in the following illustration).

2.Attach 1 adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters.

3.Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to attach the flexible connector to the adapters. Check that connector is not kinked.

A

B

C

 

H

 

D

 

 

 

E F

G

A. Gas pressure regulator

E. Adapter - Must have ½" male

B. Use pipe-joint compound

pipe thread

 

C. Adapter - Must have ½"

F. Use pipe-joint compound.

male pipe thread

G. ½" or ¾" gas pipe

D. ⁵⁄₈" min. flexible connector

H. Manual gas shutoff valve

Complete Connection

1.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.

A

B

A. Closed valve

B. Open valve

2.Test all connections by brushing on an approved noncorrosive leak-detection solution. If bubbles appear, a leak is indicated. Correct any leak found.

B

F C

D

E

A. Burner cap

B. Burner head

C. Gas tube opening

D. Burner base

E.Notch

F.Tab

Complete Installation

Electronic Ignition System

Check Operation of Surface Burners

1.Push in and turn the surface burner control knobs to the “HI” position.

The surface burner flame should light within 4 seconds. The first time a surface burner is lighted it may take longer that 4 seconds to light because of air in the gas line.

2.Check the flame on “HI” for a blue color. It should be clean and soft in character. No yellow tip, blowing or lifting of flame should occur. Occasional orange flashes are normal and reflect different elements in the air or gas.

3.Repeat at “LO” position.

4.After verifying the proper burner operation, turn the control knobs to “OFF.”

If burners do not light properly:

Turn surface burner control knob to the “OFF” position.

Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown.

Check that the gas shutoff valves are set to the “open” position.

Check that burner heads and caps are properly positioned on burner bases.

Recheck operation of surface burners. If a burner does not light at this point, contact your dealer or authorized service company for assistance.

7

Image 7
Contents 30 76,2 CM ET 36 91,4 CM Cooktop SafetyTools needed Installation RequirementsTools and Parts Location RequirementsGas and Electric Connection Locations Mobile Home Additional Installation RequirementsProduct Dimensions Installation Clearances Gas Supply Line Electrical Requirements Gas Supply Requirements Type of GasGas Pressure Regulator Installation InstructionsPrepare Cooktop for Installation Gas Supply Pressure TestingMake Gas Connection Install CooktopTo Assemble Pressure Regulator If burners do not light properly Complete InstallationTypical flexible connection Complete ConnectionOn 30 76.2 cm models Wiring DiagramsOn 36 91.4 cm models Votre sécurité et celle des autres est très importante Sécurité DE LA Table DE CuissonExigences demplacement Exigences DinstallationOutillage et pièces Dégagements de séparation à respecter Spécifications électriquesType de gaz Spécifications de lalimentation en gazCanalisation de gaz Préparation de la table de cuisson pour Linstallation Instructions DinstallationInstallation de la table de cuisson Assemblage du détendeur Raccordement au gazRaccordement typique par raccord flexible Compléter le raccordement Achever linstallationSi le brûleur ne sallume pas correctement 9761893A Schémas DE CâblageSur les modèles de 30 76,2 cm Sur les modèles de 36 91,4 cm