Whirlpool W10435039A Drain Requirements, Water Supply Requirements, Electrical Requirements

Page 6
Drain Requirements

Drain Requirements

A new drain hose is supplied with your dishwasher. If drain hose is not long enough, use a new drain hose with a maximum length of 12 ft (3.7 m) (Part Number 3385556) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the 1" (2.5 cm) drain connector of the dishwasher.

Make sure to connect drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20" (50.8 cm) minimum above the floor. It is recommended that the drain hose either be looped up and securely fastened to the underside of the counter, or be connected to an air gap.

Make sure to use an air gap if the drain hose is connected to house plumbing lower than 20" (50.8 cm) above subfloor or floor.

Use ¹₂ " minimum I.D. drain line fittings.

If required, the air gap should be installed in accordance with the air gap installation instructions. When you are connecting the air gap, a rubber hose (not provided) will be needed to connect to the waste tee or disposer inlet.

Water Supply Requirements

A hot water line with 20 to 120 psi (138 to 862 kPa) water pressure can be verified by a licensed plumber.

120°F (49°C) water at dishwasher.

³₈ " O.D. copper tubing with compression fitting or flexible braided water supply line (Part Number 4396897RP). NOTE: ¹₂ " minimum plastic tubing is not recommended.

A 90° elbow with ³₄ " hose connection with rubber washer.

Do not solder within 6" (15.2 cm) of the water inlet valve.

Electrical Requirements

Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association 1 Batterymarch Park

Quincy, MA 02269

You must have:

120-volt, 60 Hz, AC-only, 15- or 20-amp, fused electrical supply.

Copper wire only.

We recommend:

A time-delay fuse or circuit breaker.

A separate circuit.

If connecting dishwasher with a power supply cord:

Use UL Listed power supply cord kit (Part Number 4317824) marked for use with dishwasher.

Power supply cord must plug into a grounded 3 prong outlet, located in the cabinet next to the dishwasher opening. Outlet must meet all local codes and ordinances.

If connecting dishwasher with direct wiring:

Use flexible, armored or nonmetallic

sheathed, copper wire with grounding wire that meets the wiring requirements for your home and local codes and ordinances.

Use a UL Listed/CSA Approved strain relief.

6

Image 6
Contents LAVE-VAISSELLE SOUS COMPTOIR MODÈLES À TRÈS GRANDE CUVE EN PLASTIQUE INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERPLASTIC GIANT TUB MODELS INSTRUCTIONS DINSTALLATION W10435039AYou Need to TABLE OF CONTENTSDISHWASHER SAFETY Tip Over HazardIn addition, for first-time installations INSTALLATION REQUIREMENTSAll Installations Tools and PartsLocation Requirements Page Drain Requirements If connecting dishwasher with a power supply cordIf connecting dishwasher with direct wiring Water Supply RequirementsPrepare Cabinet Opening-Existing Utilities INSTALLATION INSTRUCTIONSOption A, Power Supply Cord Prepare Cabinet Opening-New UtilitiesOption B, Direct Wire Prepare and Route Water LineInstall Drain Hose Option A, Waste disposer - no air gap Option B, No waste disposer - no air gapOption C, Waste disposer - with air gap Prepare Dishwasher Excessive Weight HazardUse two or more people to move and install dishwasher Option D, No waste disposer - with air gapMake Power Supply Cord Connection Connect ground wire to green ground connector in terminal box Electrical Shock Hazard Electrically ground dishwasherDo not use an extension cord Determine Cabinet Opening Option 1, Countertop Attachment Choose Attachment OptionPrepare Water Supply Line Option 2, Side AttachmentMove Dishwasher Close to Cabinet Opening NOTE Springs should be in the same notches on left and right sides Connect to Water Supply Connect to DrainMake Direct Wire Electrical Connection Secure Dishwasher in Cabinet Opening Secure dishwasher to countertop Side mount dishwasher to cabinetElectrical Shock Hazard Plug into a grounded 3 prong outlet Complete InstallationReconnect Power Do not remove ground prong Do not use an adapterCheck Operation If Dishwasher Does Not OperateAdditional Tips