2
Check with soap solution for leaks.
If the installation is not new, you should clean it in order to avoid the obstruction of orifices and/or pilots.
To make it easier to move the appliance, the installer should loop the 3/8" copper tubing as shown in the illustration.
GAS L.P. OPERATING PRESSURE 11 inches Water Column
NATURAL GAS OPERATING PRESSURE 7 inches Water Column
I M P O R T A N T
•This range is adjusted at the factory for use with L.P. gas.
•To use this range with natural gas, you must replace the surface and oven burner orifices, call Servicio
NOTE: To operate this range with natural gas, is | |
required a kit according to the chart: | |
Range Model | Kit Number |
Model ACE2200 | 98014527 |
Model ACE2400 | 98014527 |
Model ACE3200 | 98014562 |
Model ACE3211 | 98014528 |
Model ACE3411 | 98014528 |
Model AEE2000 | 98014527 |
This kit is available at your nearest Authorized | |
Service Center. |
|
HowtoUseYourRange
HOW TO ADJUST THE FLAMES
NOTE: Do not obstruct the gas exhaust of the oven or broiler
If the range has yellow flames, it may require adjustment to the air shutters:
• How to adjust the air for surface burners:
1 | Remove the | 2 | Unscrew the | screws | 3 |
| knobs. |
| of front and below the |
| |
|
|
| manifold panel and |
| |
|
|
| remove it. |
|
|
NOTE: Because of different altitudes above sea level and variations | |||||
in the supply of gas, you may need to adjust the main air intake | |||||
to the burners. This will result in a better | |||||
a better operation. |
|
|
|
|
Adjust the air shutters individually. Light the burner, then push or pull the air shutter until you get a blue flame. Replace the manifold panel, screws and knobs.
4