NAT. GAS

CAP

FIG. B

Replace the cap in the body of the regulator, over the washer and spring, and tighten cap. See Figure D for the correct position of the washer and spring.

SCREW CAP ONTO REGULATOR AS SHOWN, FOR LP SERVICE

/

CAP,

 

 

 

 

 

FOR

NAT.

GAS

SERVICE,

 

TURN

CAP

OVER AND

SPRING

SCREW ONTO

REGULATOR

COVER

(YOU

SHOULD

BE ABLE TO

Remove the cap with the screwdriver slot and replace upside down. This plug will then have the marking “LPGIO.” Be sure not to disturb or remove the spring beneath this plug. See Figure B for correct positioning of plug.

Remove the cap, with the screwdriver slot. Remove the black insert, marked “NAT.“,from the cap. (This is a tight fit in the cap). Reverse this insert and carefully push it firmly into the hole in the cap. The marking “LP” will now be showing on the insert. Be sure the insert is pressed into the shoulder. Also, be sure not to disturb the spring in the body of the regulator.

NAT. GAS

LP GAS

 

READ ‘NAT.’ WHEN

SPRING-

 

9

\REGULATOR

FIG. E

2. Burner adjustments

a. Top burners

Remove four top burners by removing the mounting screws and lifting burner out of bracket. Then turn down the orifice hoods onto the pins. The orifices should be turned snug onto the pins being careful not to drive pin into the valve or to distort the hole through the center of the pin. Reinstall the top burners and mounting screws (see Figure 11).

_,

FIG. C

BURNER LOCATOR TAB FULLY INSERTED INTO LOCATOR SLOT AND FLUSH WITH BURNER

Replace the cap in the body of the regulator and tighten. See Figure C for the correct position of the insert.

Remove the cap, with screwdriver slot. Carefully remove the spring and washer (washer will be at bot- tom of spring). Reverse so that washer is at top of spring and reinstall spring and washer.

~CAP

‘4

E?

NAT. GAS FIG. D LP GAS

SUPPORT BRACKET.

BURNER

SUPPORT

BURNER MOUNTINGBRACKET

SCREW

TOP BURNER

i ORIFICE HOOD

i

LOCATOR

SLOT I

FIG. 11

The air shutters should be adjusted for a proper flame. To adjust the air shutter, loosen the lock screw. Move the air shutter to close the opening to decrease the air or enlarge the opening for more. Tighten the lock screw when the adjustment is complete.

9

Image 9
Contents EYE-LEVEL GAS Microwave Range EYE-LEVEL GAS Range Before you begin Check microwave for damage Space requirementsLine Pressure Testing Gas supply requirements81/Z Inlet Pressure Electrical requirements Eyelevel Mi&owave Electrical requirements Conventional EyelevelRecommended grounding method Alternate grounding methodPosition and level the range Remove shipping / base packing materialsNatural gas adjustments To access gas lineConnect gas line Check for gas leaksNatural to LP gas conversion Top burners Burner adjustmentsOven burners If you must call for service CleaningSurface burners Oven burnerConnect vent hood Space requiredDInstallingoptio ICI Hood Outlet Connection Manual Ovenlightsw ‘-b&’ GND Ignitor Whirlpool