Replacing Filters
The grease filters should be removed and cleaned at least once a month. The charcoal filters cannot be washed and should be replaced every 6 to 12 months. Do not operate the microwave oven without the filters in place. See “Assistance or Service” to reorder filters. See “General Cleaning” for cleaning instructions.
To Remove:
1.Remove the grease filters by pushing up and sliding to the side. Pull tab down until the filter drops out.
A
A.Tabs
2.Remove charcoal filters by pushing the back of each filter away from you until the front of the filter slides off the front lower lip. Swing the front of the filter down and slide out.
A
B
C
A. Upper lip
B.Spring
C.Lower lip
To Replace:
1.Replace charcoal filters by positioning the filter at the back of the opening and resting it on the springs. While pushing the filter into the springs, position the front of filter between the front upper and lower lips.
2.Replace grease filters by inserting one end into the frame. Swing other side up and slide into position.
Replacing Cooktop Light
The cooktop light is a candelabra base bulb. See “Assistance or Service” section to reorder.
To Replace:
1.Unplug microwave oven or disconnect power.
2.Remove the bulb cover mounting screw.
A
A. Mounting screw
3.Replace light. Close bulb cover. Replace mounting screw.
4.Plug in microwave oven or reconnect power.
Replacing Microwave Oven Light
The microwave oven light is a candelabra base bulb. It will automatically come on when the door is opened and when the microwave oven is operating. See “Assistance or Service” section to reorder.
To Replace:
1.Unplug microwave oven or disconnect power.
2.Remove the 2 outer vent grille mounting screws located above the cover.
3.Tip the grille forward, then lift out to remove.
4.Lift up the bulb cover.
A
A. Bulb cover
5.Replace light. Close bulb cover.
6.Reattach vent grille. Replace the mounting screws.
7.Plug in microwave oven or reconnect power.
16