Troubleshooting
Before calling service, check the possible explanations below. If these solutions fail, call Bosch service at
Problem | Possible Explanations |
|
|
|
|
Noise during operation. | Some noise is normal due to vibration and air movement. |
|
| Excessive noise indicates one of the following: |
|
| • Ductwork is too small/ undersized. |
|
| • Ductwork is too big/ oversized. |
|
| • Ductwork is loose. |
|
| • Transtition is too small/ too loose. |
|
| • Togglebolts are not tightened. |
|
| • Loose screws in trim parts, ect. |
|
Noise when not operating. | Backflow flap on outside of duct wall cap moves with the |
|
| wind. |
|
Fan motor does not work. | Power supply to hood is not sufficient. |
|
| Wires are not completely connected. |
|
Filter light does not turn off (DAH95 models only). | Light must be reset: hold filter button down for 3 seconds |
|
| (Always clean filters before resetting filter light). |
|
|
|
|
Filter light does not turn on (DAH95 models only). | Filter light will not come on until after 40 hours of operation. |
|
|
|
|
Filter light comes on. (DAH95 models only). | Indicates that filters should be cleaned. Hold button down |
|
| for 3 seconds to reset. |
|
|
|
|
Lights under hood hum. | A slight hum is normal. |
|
Operation of hood trips breaker. | • Wiring is not correct. |
|
| • Circuit is not correct. |
|
One light above Speed button blinks (DAH95 models only). | Conditions exceed allowable temperatures. Turn on next |
|
| speed level. |
|
|
|
|
All three lights above Speed button blink (DAH95 models only). | Heat sensor is not working. Call service. |
|
|
|
|