Operation - Using the Controls
Before You Begin Cooking
The blower should be turned on for about 5 minutes before cooking in order to establish air currents upward through the hood. Thus when heat, smoke, moisture, grease and cooking odors are produced, they will be carried outside instead of drifting into other rooms. Use the low speeds for normal use and the higher speeds for strong odors or fumes.
A Note about Drafts:
Drafts across the range or cooktop will reduce the effectiveness of the hood. Such drafts should be prevented when possible. The best job of ventilation in the kitchen is done when the only air currents are those created by the blower itself.
The Controls - DAH93 Models |
| The Controls - DAH95 Models | ||
Light Off | Speed |
| 1 2 3 | Off |
|
|
| ||
1 | 2 | 3 | Off Speed | Delay Off Filter Light |
The DAH93 model uses rocker switches to activate the controls. The switch is on when the lower part of the button is depressed. The switch is off when the upper part of the button is depressed.
LIGHT: Press the lower section of the button to turn lights on. Press the upper part of the button to turn the lights off.
SPEED: Press the buttons up or down for the corresponding
speed: | Off | Speed |
| LOW: |
|
1 2 3
Off Speed
MEDIUM:
1 2 3
Off Speed
HIGH:
1 2 3
The Controls - DAH94 Models
Light | Off | Speed |
1 2 3
LIGHT: Press button once to turn lights on or off.
OFF: Pressing button once turns ventilator off and resets control.
SPEED: Press the button for the corresponding speed: 1 = Low
2 = Medium
3 = High
OFF: Pressing button once turns ventilator off and resets control.
SPEED: The first time the button is pressed, it turns the fan on. The speed is low. The second time the button is pressed, the medium speed is activated. The third time the button is pressed, the speed is high.
•The lights above this button indicate the current blower speed. When the blower is on, the corresponding light is lit.
DELAY OFF: Press to turn fan on high for an additional 10 minutes. If the ventilator is off when the button is pressed, the ventilator will turn on to the high speed setting for 10 minutes. At the end of the cycle the venti- lator will turn off.
If the ventilator is on when the button is pressed, the ventilator runs for 10 minutes at the current speed then turns off.
•During this cycle, the light above the DELAY OFF button is illuminated.
•To cancel the mode, press SPEED or OFF.
FILTER: The hood is equipped with a clean filter reminder. After 40 hours of operation, the clean filter reminder light above this button will light indicationg that the filters need to be cleaned. When the indicator lights, clean the filters as described on page 4. After cleaning, press the FILTER button for 3 seconds to reset.
LIGHT:Press button once to turn lights on.
DIM: With the lights on, press and hold the light button until desired light level is achieved.
OFF: Press the button twice to turn the lights off. If the lights are dimmed,
press the button once to turn them off. HEAT SENSOR: The heat sensor notifies you that the
conditions below the hood have exceed allowable limits.
The light above the Speed button will blink. Turn on the next highest speed. The light will stop blinking when the temperature has dropped to an allowable level. If the blower is off when the heat sensor is activated, the low speed will be automatically activated.
PAGE 3