5. INSTALL THE HOOD
5.1 Run power cable to installation location. Position the hood in its intended location. Using a pen, mark the position
!
of the screws (smaller part of the keyholes, see pictures below for the (5) keyholes locations). Remove the hood.
5.2 Install (4) no. 8 x 1/2’’ screws, leaving a 1⁄8’’ gap (do not install the no. 5 screw yet).
1
2
HD0115
1 | 5 | 3 |
2 |
| 4 |
HD0122
3
4
HD0123
5.3Attach the wire clamp, insert the power cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the duct opening. Tighten the (4) screws completely, then add the last screw (screw no. 5) in the center keyhole. Make sure the damper flap opens freely.
6. CONNECT WIRING
!WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
Connect cable into wiring box using provided wire connectors.
Connect wires as follows: BLACK to BLACK, WHITE to WHITE and
GREEN or BARE wire under GREEN ground screw. DO NOT FORGET TO
CONNECT THE GROUND.
GROUND
SCREW
HD0123