Cannon Installation Instructions, Model Numbers C60DH, Location, Provision for Ventilation

Page 23

INSTALLATION INSTRUCTIONS

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge which is fitted on the back panel.

This appliance is not designed to be connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. particular attention should be given to the relevant requirements regarding ventilation.

MODEL NUMBERS C60DH

Category II2H3+ (GB)

These models are set to burn NATURAL GAS (G20) at 20 mbar but can be converted for use on BUTANE (G30) at 28-30mbar or PROPANE (G31) at 37mbar with the use of the LPG conversion kit supplied with the cooker.

GAS SAFETY (INSTALLATION & USE) REGULATIONS

It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the above regulations. It is in your interest and that of safety to ensure compliance with the law.

In the UK, CORGI registered installers work to safe standards of practice. The cooker must also be installed in accordance with BS 6172.

Failure to install the cooker correctly could invalidate the warranty liability claims and could lead to prosecution.

LOCATION

The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or shower. The cooker must not be installed in a bed-sitting room of less than 20m3.

When adjusted for use on Butane (G30) or Propane (G31), the cooker must not be installed in a room or internal space below ground level, e.g. in a basement.

PROVISION FOR VENTILATION

The room containing the cooker should have an air supply in accordance with BS 5440: Part 2.

The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements.

23

Image 23
Contents Harrogate Contents Introduction Please read the precautions below before using your cooker For Your SafetyFor Your Safety Guidance on Automatic Cooking Oven Timer OperationAutomatic Cooking Clockface Setting the Time of DAY Auto Cooking Programmes Oven Timer Operation Other Notes on Timer Operation To USE the Hotplate HotplateHOW to Deal with a FAT Fire Safety Requirements for Deep FAT FryingTo USE the Grill GrillGrill PAN Handle Main Oven FAN Cooking OvensTOP Oven Conventional Cooking To USE the TOP OvenFan Oven Cooking BakingTop Oven Cooking Oven Cooking ChartsUsing the ‘S’ Setting for Slow Cooking Slow Cook SettingOven Doors Care and CleaningOven Heat Clean Linings Replacement of Oven Light BulbCooker Finish Cleaning Method Something Wrong With Your Cooker Problem CheckDisposal of old electrical appliances Disposal of your productLocation Installation InstructionsGAS Safety Installation & USE Regulations Model Numbers C60DHBurner Technical DataG20 at 20mbar G31 at 37mbarCooker Hoods Space for FixingConversion for USE on Butane G30 or Propane G31 Unpacking the CookerLevelling Stability Chain Connecting to GAS SupplyElectrical Connection Installation and Operational Checks Page Page Extended Warranties After Sales ServiceRepair Service and Information Help Desk Genuine Parts & Accessories