•Push the Rotary Dial and select CLEAN MACHINE.
•Push the Rotary Dial.
•Then follow the instructions in chapter 18.1.
DE-SCALE MACHINE.
•To access this program set the function FILTER to NO.
•Then select within the function RINSE, the program
•Push the Rotary Dial. Follow the instructions in chapter 18.3
CHANGE FILTER.
When you use the Clearyl filter and the machine does not auto- matically remind you within three months to change it, the filter needs to be replaced with this program. To access this program manually, make sure the function FILTER is set to YES.
SELECT PRODUCT.
•Push and hold the Rotary Dial. FILTER YES.
•Turn the Rotary Dial until the display shows RINSE.
•Push the Rotary Dial and select CHANGE FILTER.
•Push the Rotary Dial.
•Then follow the instructions in chapter 14b.
17.2REMOVING STONES FROM THE BURR GRINDER If the burr grinder is blocked, proceed as follows:
• Turn off the machine by pushing the ON/OFF button (Fig. 2,B). Wait until the machine has shut down completely.
• Turn the main power switch off (Fig 1b).
• Open the bean container lid and remove all beans (scoop out beans or use a
• Remove the screw in the bean container (Fig. 23) and
push the grinder shield upwards (Fig. 24) Do not try to remove the shield completely.
•If any beans remain, remove them.
•Attach the burr grinder release tool to the upper burr (Fig. 25).
•If you cannot find this tool call
•Turn the tool
becomes loose.
Attention: Do not try to turn the tool clockwise.
•Fold the shield down and replace the screw.
•Turn machine on and test the grinder without beans to see if the blockage has disappeared.
17.3 GENERAL CLEANING INSTRUCTIONS
Never use abrasive materials or chemicals to clean the machine.
•Clean the housing with a soft, damp cloth.
•Rinse water tank daily and fill with fresh cold water.
17.4 EMPTYING THE SYSTEM BEFORE TRANSPORT
This procedure is necessary to prevent water and frost damage in case you intend to transport the machine.
SELECT PRODUCT
•Remove the frother system. Leave the steam nozzle attached (Fig. 4).
•Place a container under the steam nozzle.
•Turn the machine off. The main power switch is still on.
•Press and hold either steam button until the display shows
SYSTEM EMPTYING