CFM UVCVR36, UVSTR36 dimensions General Information, Installation Precautions, Fireplace Screen

Page 3

UVSTR / UVCVR Series Vent-Free Fireboxes

General Information

DO NOT BURN WOOD OR OTHER MATERI- ALS IN THESE FIREBOXES.

General Information

The installation must conform with local building codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest edition) and with the National Electrical Code, ANSI/NFPA70 (latest edition).

In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

NOTE: Installation and repair should be done by a qual- ified service person. The firebox should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint form carpeting, bedding material, etc. It is imperative that control compartment, burners, and circulating air passageways of the firebox be kept clean.

Any safety screen or guard removed for servicing the firebox must be replaced prior to operating the firebox.

Provide adequate combustion and ventilation air.

The flow of combustion and ventilation air MUST NOT be obstructed.

Provide adequate clearance around air openings into the combustion chamber and adequate accessibility clearance for servicing and proper operation. NEVER obstruct the opening of the firebox.

These models may NOT be installed in a bedroom or bathroom.

Glass doors are NOT available for these fireboxes.

WARNING: Check with your electronics manufactur- er before installing a television or other electronic device above this fireplace.

Installation Precautions

This Majestic Fireplaces firebox and its components have been tested and will operate safely when installed in accordance with this installation manual. Read all in- structions before starting installation, then follow these instructions carefully during installation to maximize firebox benefit and safety. Report to your dealer any parts damaged in shipment.

This firebox is a highly engineered system. Unless you use CFM Corporation components which have been designed for the system, you may create a possible fire hazard.

CFM Corporation warranty will be voided by, and CFM Corporation disclaims any responsibility for, the following actions:

Installation of any damaged firebox.

Modification of the firebox or any of the compo- nent parts thereof.

Installation other than as instructed by CFM Cor- poration.

Installation and/or use of any component part or accessory not manufactured or approved by CFM Corporation in combination or assembly with a Majestic Fireplaces firebox, notwithstand- ing any independent testing laboratory or other third party approval of such component part or accessory.

Any such action may create a possible fire hazard.

Consult your local building codes.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth de- fects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

Fireplace Screen

The fireplace screen must be in place when the firebox is operating, and unless other provisions for combustion air are made, the screen must have openings for the introduction for combustion air.

WARNING: Be sure to read complete Vent Free Gas Log Heater and Vent-Free Fire- place Installation and Operating Instruc- tions before installing this product.

7412960

3

Image 3
Contents Vent-Free Fireboxes For Your Safety Table of ContentsDescription Fireplace Screen Installation PrecautionsGeneral Information General InformationUVSTR36 Specifications Minimum Clearances Uvstr / Uvcvr Series Vent-Free FireboxesFraming InstallationInstalling Outside Air Kit PlanningInstall Gas Log Heater Connect the Gas LineCold Climate Insulation Hearth Extension FinishingAppliance surround flush with finish wall Install HoodLogs can GET Very HOT Handle only When Cool MaintenanceUvcvr Vent Free Firebox Uvstr Vent Free Firebox AKU2 AccessoriesUvstr / Uvcvr Series Vent-Free Fireboxes Limited Lifetime Warranty CFM Corporation