Finished Wall
Must be sealed with noncombustible mate- rial
Noncombustible Decorative Fac- ing
Surround
2 x 4 Finished
Header
Standoff
FP610
UVSTR / UVCVR Series Vent-Free Fireboxes
4¹⁄₄" Max.
Brick Sur- face
Extended
Hood
Fig. 11 Appliance surround flush with finish wall.
Finished Wall
Noncombustible Decorative Fac- ing
Surround
2 x 4 Finished Header
Covered Wall
Must be sealed with non- combustible material
Standoff
FP611
FP685
Fig. 13 Side view of firebox with extended hood.
Fig. 12 Facing on firebox flush with finished wall.
Install Hood
A 2" or 4" Hood can be purchased for the UVSTR36 and the UVCVR36. A Hood must be installed if the mantel falls within the dimensions and location shown in Figure 3. Failure to do so may create a fire hazard.
WARNING: When the black surround is covered by a brick surface, (Fig. 13), use an extended hood. The hood should extend out to the brick surface (Refer to Figs. 13 and 14) and be attached to the firebox. The maximum brick to noncombustible sur- face that may extend out past the black surround surface is 4¹⁄₄".
The size of the Hood required depends on BTU ratings and clearances. See the Accessories section on Page 13 for details.
Screw Slot (Fastens to
side rail from inside hood)
Use Top Slot
Screw
FP613
Fig. 14 Hood location.
7412960 | 9 |