Bertazzoni M93V manual Burner Adjustment, Appliance Electric Connection, Appliance Category

Page 4

TABLE N°1: Adaption to various types of gas

 

APPLIANCE CATEGORY:

II2H3+

 

Burner

Types of Gas

Pressure

Nozzle

 

Rater Capacity

 

Reduced

by-pass

 

 

 

 

Diameter

 

 

 

 

Capacity

Diameter

 

 

 

mbar

1/100 mm.

g/h

l/h

kw

kcal/h

kw

kcal/h

1/100 mm.

 

Natural

G20

20

72

-

95

1

860

0,48

413

34 reg.

Auxiliary

Butane

G30

30

50

73

-

1

860

0,48

413

34

 

Propane G31

37

50

71

-

1

860

0,48

413

34

 

Natural

G20

20

97

-

167

1,75

1505

0,6

516

36 reg.

Semi-Rapid

Butane G30

30

65

127

-

1,75

1505

0,6

516

36

 

Propane G31

37

65

125

-

1,75

1505

0,6

516

36

 

Natural

G20

20

115

-

286

3

2580

1,05

903

52 reg.

Rapid

Butane

G30

30

85

218

-

3

2580

1,05

903

52

 

Propane G31

37

85

214

-

3

2580

1,05

903

52

Dual

Natural

G20

20

72

-

95

1

860

0,48

413

34 reg.

Inner

Butane

G30

30

46

73

-

1

860

0,48

413

34

 

Propane G31

37

46

71

-

1

860

0,48

413

34

Dual

Natural

G20

20

102

-

334

3,5

3010

1,8

1548

65 reg.

Outer

Butane

G30

30

66

254

-

3,5

3010

1,8

1548

65

 

Propane G31

37

66

250

-

3,5

3010

1,8

1548

65

 

Natural

G20

20

125

-

286

3

2580

1

860

48 reg.

Oven

Butane

G30

30

85

218

-

3

2580

1

860

48

 

Propane G31

37

85

214

-

3

2580

1

860

48

BURNER ADJUSTMENT

1)Primary air adjustment:

Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner:

1)Remove the oven bottom.

2)Loosen the screw P and adjust the position X of the Venturi cone (Fig. 15) according to the measurements indicated in table 2.

TABLE N°2: Burner primary air regulation (indicative)

Type of gas

 

BURNER

 

Oven (mm)

Natural

G20

fully open

Butane

G30

fully open

Propane

G31

fully open

2) Burner "MINIMUM" adjustment:

Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:

1)Light the burner and set the knob to the MINIMUM position (small flame).

2)Remove the knob of the valve that is press fit on the rod of that valve.

3)If the cooker is not equipped with safety valves on the surface burners, insert a small slotted screwdriver into the hole on the valve rod (Fig. 16) and turn the choke screw to the right or left until the burner flame is adjusted to minimum. If the cooker is equipped with safety valves, the choke valve is not located in the rod hole, but on the valve body (see fig. 17).

4)Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.

Oven burner adjustment: follow the instructions below to adjust the minimum:

1)Light the burner setting the knob to the MAXIMUM position.

2)Close the oven door and operate the oven for at least 10 minutes.

3)Set the knob to the MINIMUM position (corresponding to 120°) and then remove it.

4)With a slotted screwdriver turn the choking screw (see figure 18) and, while observing the flame at the same time through the cooker porthole, evaluate the consistency of the flame so it remains on when switching quickly from the MINIMUM to the MAXIMUM position.

WARNING: The above-mentioned adjustment should be made only with methane gas burners, while for those operating with liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always operates at maximum and therefore no minimum adjustment is required.

APPLIANCE ELECTRIC CONNECTION:

The electric connection must comply with the current legal standards and regulations. Before making the connection, check that:

-The system electrical rating and the current outlets are adequate for the maximum power output of the appliance (see the label applied to the bottom of the casing).

-The outlet or the system is equipped with an efficient ground connection in accordance with the current legal standards and regulations. The company will not be responsible for the non-compliance with these instructions.

When the connection to the power supply network is made using an outlet:

-If the power cord is supplied without a plug, apply a standard plug that is suitable for the load indicated on the label. Connect the wires according to the diagram shown in FIG.19 and check that:

letter L (phase) = brown wire; letter N (neutral) = blue wire;

ground symbol = green-yellow wire;

4

Image 4
Contents 91,5x64 cm type M93/M93VDual oven Contents Installer InformationInstalling the Cooker Important Information for Installing the ApplianceBackguard Installation Instruction Room VentilationLocation and Aeration Appliance GAS ConnectionBurner Adjustment 1Primary air adjustmentBurner Minimum adjustment Appliance Electric ConnectionAppliance Maintenance Types of Power CordsReplacing Parts USE and Maintenance Manual Using BurnersGAS Burner Dimension -23 Dimension mm Control Panel DescriptionUsing the GAS Oven left oven Tips for using burners correctlyTable N5 Table N6Using the Electric Thermostat left oven Table N6Using the Thermostat with Switch in Series Right oven Using the 9 + 0 Switch left ovenUsing the Natural Conventional Electric Oven Cookers with a SINGLE-CONTROL Conventional Electric OvenUsing the Ventilated Electric Oven left oven Table N7Using the Conventional Electric Grill Using the Ventilated Electric GrillUsing the SELF-CLEANING Oven Cleaning the ApplianceAFTER-SALES Technical Service and Spare Parts Cleaning the burner flame capsPage Page Page Cod