TABLE N°1: Adaption to various types of gas |
| APPLIANCE CATEGORY: | II2H3+ |
| |||||||
Burner | Types of Gas | Pressure | Nozzle |
| Rater Capacity |
| Reduced | ||||
|
|
|
| Diameter |
|
|
|
| Capacity | Diameter | |
|
|
| mbar | 1/100 mm. | g/h | l/h | kw | kcal/h | kw | kcal/h | 1/100 mm. |
| Natural | G20 | 20 | 72 | - | 95 | 1 | 860 | 0,48 | 413 | 34 reg. |
Auxiliary | Butane | G30 | 30 | 50 | 73 | - | 1 | 860 | 0,48 | 413 | 34 |
| Propane G31 | 37 | 50 | 71 | - | 1 | 860 | 0,48 | 413 | 34 | |
| Natural | G20 | 20 | 97 | - | 167 | 1,75 | 1505 | 0,6 | 516 | 36 reg. |
Butane G30 | 30 | 65 | 127 | - | 1,75 | 1505 | 0,6 | 516 | 36 | ||
| Propane G31 | 37 | 65 | 125 | - | 1,75 | 1505 | 0,6 | 516 | 36 | |
| Natural | G20 | 20 | 115 | - | 286 | 3 | 2580 | 1,05 | 903 | 52 reg. |
Rapid | Butane | G30 | 30 | 85 | 218 | - | 3 | 2580 | 1,05 | 903 | 52 |
| Propane G31 | 37 | 85 | 214 | - | 3 | 2580 | 1,05 | 903 | 52 | |
Dual | Natural | G20 | 20 | 72 | - | 95 | 1 | 860 | 0,48 | 413 | 34 reg. |
Inner | Butane | G30 | 30 | 46 | 73 | - | 1 | 860 | 0,48 | 413 | 34 |
| Propane G31 | 37 | 46 | 71 | - | 1 | 860 | 0,48 | 413 | 34 | |
Dual | Natural | G20 | 20 | 102 | - | 334 | 3,5 | 3010 | 1,8 | 1548 | 65 reg. |
Outer | Butane | G30 | 30 | 66 | 254 | - | 3,5 | 3010 | 1,8 | 1548 | 65 |
| Propane G31 | 37 | 66 | 250 | - | 3,5 | 3010 | 1,8 | 1548 | 65 | |
| Natural | G20 | 20 | 125 | - | 286 | 3 | 2580 | 1 | 860 | 48 reg. |
Oven | Butane | G30 | 30 | 85 | 218 | - | 3 | 2580 | 1 | 860 | 48 |
| Propane G31 | 37 | 85 | 214 | - | 3 | 2580 | 1 | 860 | 48 |
BURNER ADJUSTMENT
1)Primary air adjustment:
Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner:
1)Remove the oven bottom.
2)Loosen the screw P and adjust the position X of the Venturi cone (Fig. 15) according to the measurements indicated in table 2.
TABLE N°2: Burner primary air regulation (indicative)
Type of gas |
| BURNER |
| Oven (mm) | |
Natural | G20 | fully open |
Butane | G30 | fully open |
Propane | G31 | fully open |
2) Burner "MINIMUM" adjustment:
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:
1)Light the burner and set the knob to the MINIMUM position (small flame).
2)Remove the knob of the valve that is press fit on the rod of that valve.
3)If the cooker is not equipped with safety valves on the surface burners, insert a small slotted screwdriver into the hole on the valve rod (Fig. 16) and turn the choke screw to the right or left until the burner flame is adjusted to minimum. If the cooker is equipped with safety valves, the choke valve is not located in the rod hole, but on the valve body (see fig. 17).
4)Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.
Oven burner adjustment: follow the instructions below to adjust the minimum:
1)Light the burner setting the knob to the MAXIMUM position.
2)Close the oven door and operate the oven for at least 10 minutes.
3)Set the knob to the MINIMUM position (corresponding to 120°) and then remove it.
4)With a slotted screwdriver turn the choking screw (see figure 18) and, while observing the flame at the same time through the cooker porthole, evaluate the consistency of the flame so it remains on when switching quickly from the MINIMUM to the MAXIMUM position.
WARNING: The
APPLIANCE ELECTRIC CONNECTION:
The electric connection must comply with the current legal standards and regulations. Before making the connection, check that:
-The system electrical rating and the current outlets are adequate for the maximum power output of the appliance (see the label applied to the bottom of the casing).
-The outlet or the system is equipped with an efficient ground connection in accordance with the current legal standards and regulations. The company will not be responsible for the
When the connection to the power supply network is made using an outlet:
-If the power cord is supplied without a plug, apply a standard plug that is suitable for the load indicated on the label. Connect the wires according to the diagram shown in FIG.19 and check that:
letter L (phase) = brown wire; letter N (neutral) = blue wire;
ground symbol =