4.For LPG models the gas supply is connected to the regulator which is supplied loose. The inlet connection has a 1/2” B.S.P. male thread. IT IS ESSENTIAL THAT THE ELBOW ON THE APPLIANCE BE HELD FIRMLY WITH A SPANNER WHEN CONNECTING THE SUPPLY. DO NOT OVER TIGHTEN. The regulated pressure For LPG is 11” w.c. (See Fig. 5A).

5.For NG models the gas supply is connected to the regulator which is supplied loose. The inlet connection has a 1/2” B.S.P. male thread. IT IS ESSENTIAL THAT THE ELBOW ON THE APPLIANCE BE HELD FIRMLY WITH A SPANNER WHEN CONNECTING THE SUPPLY. DO NOT OVER TIGHTEN. The regulated pressure For NG is 4” w.c. (See Fig. 5A).

6.For gas inlet position of appliance refer Fig 5A and 5B. After installing the gas supply and making all connections check thoroughly for possible leaks. Turn all control knobs on the unit to ‘OFF’ position. Open the valve on the gas supply. Using a soap and water solution check each gas connection one at the time, by brushing the solution over the connection. Presence of bubbles will indicate a leak. Tighten the fitting and re- check for leaks. If it is not possible to correct the leak, replace fitting. Under no circumstances use matches or flame for checking leaks.

It is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage

Fig.5B

 

Inches

mm

A

1 9/16

45

B

8 ¼

210

C

8 ½

215

D

1/8

22

Fig.5A

7.To checking inlet pressure at the appliance operate as follow:

a)Disconnect electric power before pressure checking be carried out.

b)Take off one of the gas burner cap and the relative flame spreader in order to get access to the burner injector.

c)Put in position the pressure detector directly on the burner injector afterward open the relative burner knob at maximum position keeping it pressed, then measure the outlet pressure from the burner injector.

d)Once the pressure checking has been carried out, replace the burner cap and flame spreader in the correct and original position and re-connect electric power to the appliance.

8.Turn on appliance control cock and light each burner. Check for a clear blue flame without yellow tipping. If burners show any abnormalities check that they are located properly and in line with the injector nipple.

5

Image 5
Contents Models P34 5 00 Index Installation manualOverhead clearances Minimum values Inserting the hotplateRequirements Gas connection Attaching the hotplateSide clearances Minimum values L10Inches Instructions for assembly of load bearing bottom protection Wiring diagramsWiring diagram description Electrical connectionNatural a Table a Adapting to different types of gasRegulation of the Minimum on the burners Service & maintenance instructionsRegulation of burners Tips for using burners correctly Using burnersUser instructions DescriptionsNever use abrasive cleaners Cleaning the applianceTable B Burner Recommended pan diameters inches mm Correct usage of pansDealer /Importer Name, address, phone Name PhoneModèles P34 5 00 Manuel pour l’installation Insertion de la table de cuisson Fixation de la table de cuisson ExigencesDistances des meubles suspendus Valeurs minimum Distances latérales Valeurs minimumBranchement du gaz Description du schéma de câblage Branchement électriqueSchémas de câblage Protection DU Fond Portant Rivet M5 Plan DE Travail Instructions de montage de la protection du fond portantRéglage du Minimum sur les brûleurs Tableau a Adaptation aux différents types de gazRéglage des brûleurs Instructions pour l’utilisateur Instructions de service et d’entretienUtilisation correcte des casseroles Utilisation des brûleursSuggestions pour une utilisation correcte des brûleurs Revendeur /Importateur Nom, adresse, téléphone Service après venteNettoyage de l’appareil Cablage Circuit Diagram Exploded View