SECTION VIEW OF THE RIGHT ASSEMBLY
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig. 5A. For LP Gas fit assembly described in fig. 5A.
-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 6) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE A shown below.
fig.6
TABLE A: Adapting to different types of gas
fig.7
Gas |
| NATURAL (A) |
|
|
| LP (E) |
|
| ||
|
|
|
|
|
|
|
|
|
| |
Burner | Pressure | Inj. size | Input Rate | Simmer Rate | Pressure | Inj. size | Input Rate | Simmer Rate | ||
Type | [i.w.c.] | 1/100mm | [BTU/h] | [BTU/h] | [i.w.c.] | 1/100mm | [BTU/h] |
| [BTU/h] | [1/100mm] |
|
|
|
|
|
|
|
|
|
|
|
Auxiliary |
| 0,90 | 3400 | 900 |
| 0,54 | 3400 |
| 900 | 29 |
| 1,18 | 6100 | 1500 |
| 0,70 | 6100 |
| 1500 | 37 | |
Rapid | 4" | 1,55 | 10400 | 3700 | 11" | 0,92 | 10400 |
| 3700 | 58 |
|
|
|
|
|
|
|
|
|
|
|
Fish |
| 1,55 | 10200 | 4000 |
| 0,92 | 10200 |
| 4000 | 61 |
Triple Ring |
| 1,65 | 11900 | 5300 |
| 1,02 | 12300 |
| 5300 | 73 |
|
|
|
|
|
|
|
|
|
|
|
CAUTION: save the orifices removed from the appliance for future use
7